MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.brachy.2020.02.007

Медицинская библиотека · Brachytherapy · 2020

Evaluation of the urethral α/β ratio and tissue repair half-time for iodine-125 prostate brachytherapy with or without supplemental external beam radiotherapy.

Gocho Toshio, Hori Masakazu, Fukushima Yuuki, Someya Masanori, Kitagawa Mio, Hasegawa Tomokazu, Tsuchiya Takaaki, Hareyama Masato, Takagi Masaru, Hashimoto Kohei, Masumori Naoya, Sakata Koh-Ichi

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the correlation between postimplant dosimetric quantifiers and the genitourinary (GU) toxicity of low-dose rate brachytherapy for prostate cancer.

METHODS AND MATERIALS: The minimum urethral dose (UD10, 30, and 90) and the percent volume of the urethra receiving the prescription dose (V100, V150) were calculated from the postimplant dose-volume histograms of 182 patients. We then calculated various urethral biologically equivalent doses (uBEDs) using different values of the α/β ratio and tissue repair half-time (t1/2) and examined the correlations with GU toxicity.

RESULTS

Common dosimetric quantifiers, such as UD90 (brachytherapy) + UD50 (external beam radiotherapy), showed no correlation with Grade ≥ 2 GU toxicity. There was a significant correlation between Grade ≥2 GU toxicity and uBED when the α/β value was 0.5 or 1 Gy and t1/2 was 0.5-2.5 h. An uBED (α/β = 1.0, t1/2 = 0.5) had the largest hazard ratio for GU toxicity, and it was also significantly correlated with Grade ≥ 2 GU toxicity according to multivariate analysis.

CONCLUSIONS

We observed a significant correlation of uBED with GU toxicity when α/β was 0.5 or 1.0 Gy and t1/2 was 0.5-2.5 h. As the simple formula we used has not been verified in basic experiments, more data are needed to validate our results.

Для цитирования: Gocho Toshio, Hori Masakazu, Fukushima Yuuki, Someya Masanori, Kitagawa Mio, Hasegawa Tomokazu, Tsuchiya Takaaki, Hareyama Masato, Takagi Masaru, Hashimoto Kohei, Masumori Naoya, Sakata Koh-Ichi. Evaluation of the urethral α/β ratio and tissue repair half-time for iodine-125 prostate brachytherapy with or without supplemental external beam radiotherapy.. Brachytherapy. 2020. DOI: 10.1016/j.brachy.2020.02.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.