Chen Yanshan, Feng Lijuan, Huang Zixuan, Zou Wenbin, Luo Guibo, Dai Guochao, Zhao Weidong, Cai Wenli, Luo Mingyue

Аннотация

OBJECTIVE: The aim of this study was to compare diatrizoate and iohexol regarding patient acceptance and fecal-tagging performance in noncathartic computed tomography colonography.

METHODS: This study enrolled 284 volunteers with fecal tagging by either diatrizoate or iohexol at an iodine concentration of 13.33 mg/mL and an iodine load of 24 g. Patient acceptance was rated on a 4-point scale of gastrointestinal discomfort. Two gastrointestinal radiologists jointly analyzed image quality, fecal-tagging density and homogeneity, and residual contrast agent in the small intestine. The results were compared by the generalized estimating equation method.

RESULTS: Patient acceptance was comparable between the 2 groups (3.95 ± 0.22 vs 3.96 ± 0.20, P = 0.777). The diatrizoate group had less residual fluid and stool than the iohexol group ( P = 0.019, P = 0.004, respectively). There was no significant difference in colorectal distention, residual fluid, and stool tagging quality between the 2 groups (all P 's > 0.05). The mean 2-dimensional image quality score was 4.59 ± 0.68 with diatrizoate and 3.60 ± 1.14 with iohexol ( P < 0.001). The attenuation of tagged feces was 581 ± 66 HU with diatrizoate and 1038 ± 117 HU with iohexol ( P < 0.001). Residual contrast agent in the small intestine was assessed at 55.3% and 62.3% for the diatrizoate group and iohexol group, respectively ( P = 0.003).

CONCLUSIONS: Compared with iohexol, diatrizoate had better image quality, proper fecal-tagging density, and more homogeneous tagging along with comparable excellent patient acceptance, and might be more suitable for fecal tagging in noncathartic computed tomography colonography.