Gasless Total Laparoscopic Hysterectomy with New Abdominal-Wall Retraction System.

Kim Mi Kyoung, Hwang Jong Ha, Kim Jang-Heub, Kim Soo Rim, Lee Sae Bom, Kim Bo Wook

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVES

Gasless laparoscopy is an alternative method to reduce the number of carbon dioxide (CO2)-insufflated, pneumoperitoneum-related problems including shoulder pain, postoperative nausea/vomiting, and decreased cardiopulmonary function. In this study, we investigated the feasibility of gasless total laparoscopic hysterectomy (TLH) with a newly developed abdominal-wall retraction system.

METHODS

Abdominal-wall retraction for gasless laparoscopy was performed using the newly developed J-shape retractor and the Thompson surgical retractor. Surgical outcomes between gasless TLH and conventional CO2-based TLH were compared for each of 40 patients for the period from January 2017 to October 2019.

RESULTS

Between gasless TLH and conventional CO2-based TLH, no significant differences were observed for age, body mass index, parity, or surgical indications. The mean retraction setup time from skin incision was 7.4 min (range: 4-12 min) with gasless TLH. The mean total operation times were 87.9 min (range: 65-170) with gasless TLH and 90 min (range: 45-180) with conventional TLH, which showed no significant difference. Estimated blood loss and uterus weight also showed no significant intergroup difference. No major complications related to the ureter, bladder, or bowel were encountered.

CONCLUSION

Our new abdominal-wall retraction system for gasless TLH allowed for easy setup and a proper operation field in the performance of laparoscopic hysterectomy.

Для цитирования: Kim Mi Kyoung, Hwang Jong Ha, Kim Jang-Heub, Kim Soo Rim, Lee Sae Bom, Kim Bo Wook. Gasless Total Laparoscopic Hysterectomy with New Abdominal-Wall Retraction System.. JSLS : Journal of the Society of Laparoendoscopic Surgeons. 2020. DOI: 10.4293/jsls.2019.00061.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.