Reference Intervals for Thyrotropin Hormone in the General Andean Population of Quito-Ecuador Using Electrochemiluminescence Assay.

Villagómez Torres Diana, Sáenz-Flor Klever V, Velepucha Pablo S, Cordova Andree O

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Thyroid function is one of the most current procedures in the evaluation of endocrine function performed in daily practice; the reference intervals for thyrotropin (TSH) depend on the assay technology and the instruments in each laboratory. The main objective of this study is to determine the thyrotropin reference values in patients considered as euthyroid, living in the Andean region, at 2850 meters above sea level (Quito, Ecuador).

METHODS

A cross-sectional, analytical, epidemiological study was conducted using a sample of 595 healthy adult volunteer donors from the Military Hospital Blood Bank in Quito-Ecuador. Serum samples were analyzed for thyrotropin levels using electrochemiluminescence. The reference values were calculated using recommendations from the CLSI C28A3 guide.

RESULTS

The mean age of the overall sample was 35.7 (7.2) years, 50.9% (n = 303) were women. TSH recovered in the total sample showed a median of 2.64 mIU/L (2.5th-97.5th percentiles: 0.91-8.35 mIU/L); after removing outliers the reference values for the studied population were 0.87 to 5.21 mIU/L, without differences by sex.

CONCLUSIONS

General laboratory practice should improve harmonization of TSH assays. This is a must in daily clinical practice, since it would allow us to share real reference intervals in an established population and may be related to the presence or absence of thyroid pathology.

Для цитирования: Villagómez Torres Diana, Sáenz-Flor Klever V, Velepucha Pablo S, Cordova Andree O. Reference Intervals for Thyrotropin Hormone in the General Andean Population of Quito-Ecuador Using Electrochemiluminescence Assay.. The journal of applied laboratory medicine. 2022. DOI: 10.1093/jalm/jfac015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.