MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/intqhc/mzz075

Медицинская библиотека · International journal for quality in health care : journal of the International Society for Quality in Health Care · 2019

Zap it track it: the application of Lean Six Sigma methods to improve the screening system of low-grade mucinous neoplasms of the appendix in an acute hospital setting.

McGrath Kathleen, Casserly Mairéad, O'mara Freda, Mulsow Jurgen, Shields Conor, Staunton Oonagh, Teeling Seán Paul, Ward Marie

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To improve the number of patients receiving annual computed tomography (CT) scan and tumour markers, who are diagnosed with low-grade mucinous neoplasms (LAMN).

DESIGN

A pre-/post-intervention design was employed using Lean Six Sigma methods to identify gaps in the screening system and to develop and implement solutions for a more robust, auditable screening programme.

SETTING

The patients diagnosed with LAMN of the appendix referred to the acute hospital and are enrolled in the screening service.

PARTICIPANTS

Consultant colorectal surgeons, cancer nurse specialist, colorectal medical team and quality improvement staff.

INTERVENTIONS: Diagnostic tools identified gaps in the current process. A set of improvements were implemented to standardize the pathway for referral and surveillance of patients, provide information on the condition and treatment and standardize and track information received by patients and their referring hospital.

MAIN OUTCOME MEASURE(S): Pre and post-intervention outcome measures were taken for the number of patients who receive an annual CT of thoracic, abdomen and peritoneum and tumour markers and number of patients who receive information and contact details.

RESULTS

At baseline, of the 28 patients that met the inclusion criteria only 61% had a correct follow-up. Following the implementation of improvements, 78% of patients had correct follow-up and 90% had received information.

CONCLUSIONS

Gaps in the current cancer screening system were identified and improvements implemented a reduced number of patients having an incorrect follow-up. Findings are applicable across all precancerous screening systems irrespective of the type of malignancy. The methods used empowered patients and fostered an interdisciplinary team approach to care.

Для цитирования: McGrath Kathleen, Casserly Mairéad, O'mara Freda, Mulsow Jurgen, Shields Conor, Staunton Oonagh, Teeling Seán Paul, Ward Marie. Zap it track it: the application of Lean Six Sigma methods to improve the screening system of low-grade mucinous neoplasms of the appendix in an acute hospital setting.. International journal for quality in health care : journal of the International Society for Quality in Health Care. 2019. DOI: 10.1093/intqhc/mzz075.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.