DOI 10.1016/j.radonc.2024.110409

Медицинская библиотека · Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2024

Robustness of intensity modulated proton treatment of esophageal cancer for anatomical changes and breathing motion.

Canters Richard, van der Klugt Kim, Trier Taasti Vicki, Buijsen Jeroen, Ta Bastiaan, Steenbakkers Inge, Houben Ruud, Vilches-Freixas Gloria, Berbee Maaike

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: In this study, we assessed the robustness of intensity modulated proton therapy (IMPT) in esophageal cancer for anatomical variations during treatment.

METHODS

The first sixty esophageal cancer patients, treated clinically with chemoradiotherapy were included. The treatment planning strategy was based on an internal target volume (ITV) approach, where the ITV was created from the clinical target volumes (CTVs) delineated on all phases of a 4DCT. For optimization, a 3 mm isotropic margin was added to the ITV, combined with robust optimization using 5 mm setup and 3 % range uncertainty. Each patient received weekly repeat CTs (reCTs). Robust plan re-evaluation on all reCTs, and a robust dose summation was performed. To assess the factors influencing ITV coverage, a multivariate linear regression analysis was performed. Additionally, clinical adaptations were evaluated.

RESULTS

The target coverage was adequate (ITV V94%>98 % on the robust voxel-wise minimum dose) on most reCTs (91 %), and on the summed dose in 92 % of patients. Significant predictors for ITV coverage in the multivariate analysis were diaphragm baseline shift and water equivalent depth (WED) of the ITV in the beam direction. Underdosage of the ITV mainly occurred in week 1 and 4, leading to treatment adaptation of eight patients, all on the first reCT.

CONCLUSION

Our IMPT treatment of esophageal cancer is robust for anatomical variations. Adaptation appears to be most effective in the first week of treatment. Diaphragm baseline shifts and WED are predictive factors for ITV underdosage, and should be incorporated in an adaptation protocol.

Для цитирования: Canters Richard, van der Klugt Kim, Trier Taasti Vicki, Buijsen Jeroen, Ta Bastiaan, Steenbakkers Inge, Houben Ruud, Vilches-Freixas Gloria, Berbee Maaike. Robustness of intensity modulated proton treatment of esophageal cancer for anatomical changes and breathing motion.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2024. DOI: 10.1016/j.radonc.2024.110409.