MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1253/circj.cj-24-1031

Медицинская библиотека · Circulation journal : official journal of the Japanese Circulation Society · 2025

Deep Learning-Based Fully Automated Aortic Valve Leaflets and Root Measurement From Computed Tomography Images - A Feasibility Study.

Yamauchi Haruo, Aoyama Gakuto, Tsukihara Hiroyuki, Ino Kenji, Tomii Naoki, Takagi Shu, Fujimoto Katsuhiko, Sakaguchi Takuya, Sakuma Ichiro, Ono Minoru

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The aim of this study was to retrain our existing deep learning-based fully automated aortic valve leaflets/root measurement algorithm, using computed tomography (CT) data for root dilatation (RD), and assess its clinical feasibility.

METHODS AND

RESULTS

67 ECG-gated cardiac CT scans were retrospectively collected from 40 patients with RD to retrain the algorithm. An additional 100 patients' CT data with aortic stenosis (AS, n=50) and aortic regurgitation (AR) with/without RD (n=50) were collected to evaluate the algorithm. 45 AR patients had RD. The algorithm provided patient-specific 3-dimensional aortic valve/root visualization. The measurements of 100 cases automatically obtained by the algorithm were compared with an expert's manual measurements. Overall, there was a moderate-to-high correlation, with differences of 6.1-13.4 mm2for the virtual basal ring area, 1.1-2.6 mm for sinus diameter, 0.1-0.6 mm for coronary artery height, 0.2-0.5 mm for geometric height, and 0.9 mm for effective height, except for the sinotubular junction of the AR cases (10.3 mm) with an indefinite borderline over the dilated sinuses, compared with 2.1 mm in AS cases. The measurement time (122 s) per case by the algorithm was significantly shorter than those of the experts (618-1,126 s).

CONCLUSIONS

This fully automated algorithm can assist in evaluating aortic valve/root anatomy for planning surgical and transcatheter treatments while saving time and minimizing workload.

Для цитирования: Yamauchi Haruo, Aoyama Gakuto, Tsukihara Hiroyuki, Ino Kenji, Tomii Naoki, Takagi Shu, Fujimoto Katsuhiko, Sakaguchi Takuya, Sakuma Ichiro, Ono Minoru. Deep Learning-Based Fully Automated Aortic Valve Leaflets and Root Measurement From Computed Tomography Images - A Feasibility Study.. Circulation journal : official journal of the Japanese Circulation Society. 2025. DOI: 10.1253/circj.cj-24-1031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.