MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41467-019-11014-1

Медицинская библиотека · Nature communications · 2019

A zwitterionic near-infrared fluorophore for real-time ureter identification during laparoscopic abdominopelvic surgery.

de Valk Kim S, Handgraaf Henricus J, Deken Marion M, Sibinga Mulder Babs G, Valentijn Adrianus R, Terwisscha van Scheltinga Anton G, Kuil Joeri, van Esdonk Michiel J, Vuijk Jaap, Bevers Rob F, Peeters Koen C, Holman Fabian A, Frangioni John V, Burggraaf Jacobus, Vahrmeijer Alexander L

СтатьяРандомизированное исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАVideo-Audio MediaПеревод пока не подготовлен

Аннотация

Iatrogenic injury of the ureters is a feared complication of abdominal surgery. Zwitterionic near-infrared fluorophores are molecules with geometrically-balanced, electrically-neutral surface charge, which leads to renal-exclusive clearance and ultralow non-specific background binding. Such molecules could solve the ureter mapping problem by providing real-time anatomic and functional imaging, even through intact peritoneum. Here we present the first-in-human experience of this chemical class, as well as the efficacy study in patients undergoing laparoscopic abdominopelvic surgery. The zwitterionic near-infrared fluorophore ZW800-1 is safe, has pharmacokinetic properties consistent with an ideal blood pool agent, and rapid elimination into urine after a single low-dose intravenous injection. Visualization of structure and function of the ureters starts within minutes after ZW800-1 injection and lasts several hours. Zwitterionic near-infrared fluorophores add value during laparoscopic abdominopelvic surgeries and could potentially decrease iatrogenic urethral injury. Moreover, ZW800-1 is engineered for one-step covalent conjugatability, creating possibilities for developing novel targeted ligands.

Для цитирования: de Valk Kim S, Handgraaf Henricus J, Deken Marion M, Sibinga Mulder Babs G, Valentijn Adrianus R, Terwisscha van Scheltinga Anton G, Kuil Joeri, van Esdonk Michiel J, Vuijk Jaap, Bevers Rob F, Peeters Koen C, Holman Fabian A, Frangioni John V, Burggraaf Jacobus, Vahrmeijer Alexander L. A zwitterionic near-infrared fluorophore for real-time ureter identification during laparoscopic abdominopelvic surgery.. Nature communications. 2019. DOI: 10.1038/s41467-019-11014-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.