DOI 10.1002/lsm.10031

Медицинская библиотека · Lasers in surgery and medicine · 2002

Transscleral optical coherence tomography--an experimental study in ex-vivo human eyes.

Hoerauf Hans, Winkler Jörg, Scholz Christian, Wirbelauer Christopher, Gordes Roswitha S, Koch Peter, Engelhardt Ralf, Laqua Horst, Birngruber Reginald

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

To evaluate the potentials of a 1310-nm optical coherence tomography (OCT) system to penetrate the highly backscattering sclera in enucleated human eyes and provide visualization of intraocular structures by transscleral imaging.

STUDY DESIGN/MATERIALS AND

METHODS

OCT-images were generated by an experimental prototype (Medical Laser Center, Lübeck, Germany) using a superluminescence diode with a wavelength of 1310 nm. OCT-images were taken from two enucleated human eyes using 100-200 axial scans with 60 Hz line scan frequency and compared to subsequent histologic sections.

RESULTS

Transscleral OCT allowed penetration of the sclera and the anterior chamber angle could be completely identified. Some change within the anterior eye segment could be demonstrated with high accuracy. Additionally, limited demonstration of the ciliary body region was achieved. Due to limited signal intensity no detailed imaging of the pars plana and pars plicata region was possible. However, more posterior measurements allowed transscleral visualization of a retinal detachment.

CONCLUSIONS

OCT using lightsources with a wavelength longer than that used in conventional OCT provides a promising imaging technique at high resolution allowing transscleral imaging of the anterior eye segment.

Для цитирования: Hoerauf Hans, Winkler Jörg, Scholz Christian, Wirbelauer Christopher, Gordes Roswitha S, Koch Peter, Engelhardt Ralf, Laqua Horst, Birngruber Reginald. Transscleral optical coherence tomography--an experimental study in ex-vivo human eyes.. Lasers in surgery and medicine. 2002. DOI: 10.1002/lsm.10031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.