Real-time optical coherence tomography of the anterior segment at 1310 nm.

Radhakrishnan S, Rollins A M, Roth J E, Yazdanfar S, Westphal V, Bardenstein D S, Izatt J A

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Recent advances in high-speed scanning technology have enabled a new generation of optical coherence tomographic (OCT) systems to perform imaging at video rate. Here, a handheld OCT probe capable of imaging the anterior segment of the eye at high frame rates is demonstrated for the first time.

OBJECTIVE

To demonstrate real-time OCT imaging of anterior segment structures.

DESIGN

Survey of anterior segment structures in normal human subjects.

SETTING

Laboratory.

MAIN OUTCOME MEASURES: Achieving real-time imaging of the anterior segment, satisfactory image quality, and convenience of a handheld probe.

RESULTS

Optical coherence tomographic imaging of the anterior segment of the eyes of human subjects was performed using 1310-nm wavelength light with an image rate of 8 frames per second. Imaging trials demonstrated clear resolution of corneal epithelium and stroma, sclerocorneal junction, sclera, iris pigment epithelium and stroma, and anterior lens capsule. The anterior chamber angle was clearly visualized. Limited imaging of the ciliary body was performed. Real-time imaging of pupillary constriction in response to light stimulus was also performed.

CONCLUSION

High-speed OCT at 1310-nm wavelength is a potentially useful technique for noninvasive assessment of anterior segment structures.

CLINICAL RELEVANCE: Our results suggest that real-time OCT has potential applications in glaucoma evaluation and refractive surgery.

Для цитирования: Radhakrishnan S, Rollins A M, Roth J E, Yazdanfar S, Westphal V, Bardenstein D S, Izatt J A. Real-time optical coherence tomography of the anterior segment at 1310 nm.. Archives of ophthalmology (Chicago, Ill. : 1960). 2001. DOI: 10.1001/archopht.119.8.1179.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.