Digital image composition in long-leg radiography with a flat-panel detector: first clinical experiences.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Völk Marcus, Angele Peter, Hamer Okka, Feuerbach Stefan, Strotzer Michael
Аннотация
RATIONALE AND OBJECTIVES: The purpose of this study was to evaluate the image quality of composed long-leg examinations with a large-area, flat-panel x-ray detector.
METHODS: Thirty-five consecutive patients were included in this study. All images were obtained with a kilovoltage setting identical with conventional radiographies of speed class 400; amperage values were reduced by 50% compared with standard dose. After acquisition, the images were transferred to a workstation where the whole image was reconstructed using a generalized correlation method. Images were presented to 3 observers. Examination quality was ranked on a 3-point scale: 1 = no manual adjustment necessary; 2 = composition required manual correction; 3 = no composition possible.
RESULTS: Patient rankings were 31/35 (88.6%) in category 1, 3/35 (8.6%) in category 2, and 1/35 (2.8%) in category 3 (primarily due to an application error).
CONCLUSIONS: The analysis of the first clinical examinations of long-leg radiographies with a 43 cm x 43 cm flat-panel detector demonstrates very good reliability of the digital image composition.
METHODS: Thirty-five consecutive patients were included in this study. All images were obtained with a kilovoltage setting identical with conventional radiographies of speed class 400; amperage values were reduced by 50% compared with standard dose. After acquisition, the images were transferred to a workstation where the whole image was reconstructed using a generalized correlation method. Images were presented to 3 observers. Examination quality was ranked on a 3-point scale: 1 = no manual adjustment necessary; 2 = composition required manual correction; 3 = no composition possible.
RESULTS: Patient rankings were 31/35 (88.6%) in category 1, 3/35 (8.6%) in category 2, and 1/35 (2.8%) in category 3 (primarily due to an application error).
CONCLUSIONS: The analysis of the first clinical examinations of long-leg radiographies with a 43 cm x 43 cm flat-panel detector demonstrates very good reliability of the digital image composition.