Journal of AOAC International · 2020
Evaluation of the MC-Media Pad® Rapid Aerobic Count Device for the Enumeration of Total Aerobic Counts in a Variety of Foods: Collaborative Study, First Action Official MethodSM 2019.02.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Bastin Benjamin, Klass Nicole, Crowley Erin, Agin James, Lindhardt Charlotte, Chollet Renaud
Аннотация
BACKGROUND: The MC-Media Pad® Rapid Aerobic Count (RAC) is a ready-to-use culture device combining a test pad coated with medium and water absorption polymers that are designed for the rapid quantification of total aerobic bacteria in food products.
OBJECTIVE: The MC-Media Pad RAC was compared to the U.S. Department of Agriculture Food Safety and Inspection Service Microbiology Laboratory Guidebook, Chapter 3.02: Quantitative Analysis of Bacteria in Foods as Sanitary Indicators for raw ground pork and the Standard Methods for the Examination of Dairy Products, Chapter 6: Microbial Count Methods for yogurt drink.
METHOD: The candidate method was evaluated against the reference methods using a paired study design in a multi-collaborator study, following the current AOAC INTERNATIONAL Official Methods of AnalysisSM Appendix J guidelines. Three target contamination levels (low, medium, and high) were evaluated. MC-Media Pad RAC devices were enumerated after 24 and 48 h of incubation.
RESULTS: Plate counts obtained by both methods were log10-transformed and the difference of means (including 95% confidence intervals), repeatability SD, and reproducibility SD were determined for each contamination level. All 95% confidence intervals for mean difference fell easily within ±0.10, the performance requirement being ±0.5.
CONCLUSION: The MC-Media Pad RAC (for both 24 and 48 h) and both reference methods for each contamination level were therefore shown to be equivalent, with 97.5% confidence.
HIGHLIGHTS: The new method offers a convenient alternative to the reference methods for detection of aerobic plate count in food products, yielding reliable and comparable results in 24 or 48 h compared to 48 h for the reference methods.
OBJECTIVE: The MC-Media Pad RAC was compared to the U.S. Department of Agriculture Food Safety and Inspection Service Microbiology Laboratory Guidebook, Chapter 3.02: Quantitative Analysis of Bacteria in Foods as Sanitary Indicators for raw ground pork and the Standard Methods for the Examination of Dairy Products, Chapter 6: Microbial Count Methods for yogurt drink.
METHOD: The candidate method was evaluated against the reference methods using a paired study design in a multi-collaborator study, following the current AOAC INTERNATIONAL Official Methods of AnalysisSM Appendix J guidelines. Three target contamination levels (low, medium, and high) were evaluated. MC-Media Pad RAC devices were enumerated after 24 and 48 h of incubation.
RESULTS: Plate counts obtained by both methods were log10-transformed and the difference of means (including 95% confidence intervals), repeatability SD, and reproducibility SD were determined for each contamination level. All 95% confidence intervals for mean difference fell easily within ±0.10, the performance requirement being ±0.5.
CONCLUSION: The MC-Media Pad RAC (for both 24 and 48 h) and both reference methods for each contamination level were therefore shown to be equivalent, with 97.5% confidence.
HIGHLIGHTS: The new method offers a convenient alternative to the reference methods for detection of aerobic plate count in food products, yielding reliable and comparable results in 24 or 48 h compared to 48 h for the reference methods.