Chinese journal of traumatology = Zhonghua chuang shang za zhi · 2001
Changes of blood circulation of the extremity after external fixation for tibia shaft defect: an experimental study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yang L, Li Q, Zhou Z
Аннотация
OBJECTIVE: To assess and compare two approaches, end to end compression with lengthening (EECL) and segmental bone transport by lengthening (STBL), for long tubular bone defect and nonunion.
METHODS: Ten goats were used to establish the bone defect model of the mid-tibia. The bone defect ends were shortened step by step with a sulcated half-ring external fixator. Changes of the blood flow of the distal extremity were measured with pulse-Doppler monitor and angiography.
RESULTS: The blood flow in the distal extremity was not affected when bone defect was less than 15% of the original length. Blood circulatory disorder would appear in the distal extremity when bone defect ranged 15%-20% of the original length. The necrosis would appear in the extremity because of the blood circulatory obstacle when bone defect was more than 20% of the original length.
CONCLUSIONS: EECL is an appropriate alternative of treatments if bone defect is less than 15%; while SBTL may be feasible if bone defect is over 20% of the original length. When bone defect ranges between 15% and 20%, EECL should be applied with great care on condition of keeping watch on the extremity circulation with pulse-Doppler monitor.
METHODS: Ten goats were used to establish the bone defect model of the mid-tibia. The bone defect ends were shortened step by step with a sulcated half-ring external fixator. Changes of the blood flow of the distal extremity were measured with pulse-Doppler monitor and angiography.
RESULTS: The blood flow in the distal extremity was not affected when bone defect was less than 15% of the original length. Blood circulatory disorder would appear in the distal extremity when bone defect ranged 15%-20% of the original length. The necrosis would appear in the extremity because of the blood circulatory obstacle when bone defect was more than 20% of the original length.
CONCLUSIONS: EECL is an appropriate alternative of treatments if bone defect is less than 15%; while SBTL may be feasible if bone defect is over 20% of the original length. When bone defect ranges between 15% and 20%, EECL should be applied with great care on condition of keeping watch on the extremity circulation with pulse-Doppler monitor.