Journal of biomedical materials research · 2001

Mechanical and histological evaluations of hydroxyapatite-coated and noncoated Ti6Al4V implants in tibia bone.

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chang C K, Wu J S, Mao D L, Ding C X

Аннотация

This paper evaluates the behavior of hydroxyapatite (HAP) coated and noncoated Ti6Al4V implants in dog tibia after 3 and 5 months implantation. HPA-coated implants were obtained by plasma spraying. XRD, SEM, and EPMA were employed to estimate the coating characteristics and their behavior in vivo. Investigation of material characteristics showed that the as-received coatings consisted mainly of amorphism and HAP phase. Other phases such as TCP and CaO were identified due to thermal changes of HAP particles in plasma flame. SEM micrographs showed a typical microstructure of plasma-sprayed coating. The as-received coating was formed by well-melted pancake-like splats that lead to a dense coating with a rough surface. Lamellar structure, micropores, and microcracks, observed inside the coating, are characteristic of plasma spraying. Push-out tests revealed that HAP coating had a significant promotion of interfacial shear strength. The shear strength between bone and HAP-coated implants was much higher than that between bone and noncoated implants due to the different bone-implant interfaces formed after implantation. SEM observation revealed a direct attachment between HAP coating and newly formed bone. However, noncoated implants were separated from newly formed bone by fibrous tissues. Ti ions were found to be released into the surrounding environment after long time immersion in body fluid, and thus caused low shear strength. Prolongation of implantation time had different effects on shear strength. It improved the shear strength between HAP-coated implant and newly formed bone. However, it had little effect on that between noncoated implant and surrounding tissues.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты