Hepatic Histotripsy: Jet Ventilation Decreases the Effect of Respiratory Motion in A Porcine Liver Model.

Winterholler J Erik, Kisting Meridith A, Falk Katrina L, Kisting Adrienne L, Jentink Madeline S, White Jim K, Lubner Meghan G, Laeseke Paul F, Knavel Koepsel Erica M, Swietlik John F, Hinshaw J Louis, Ferreira Tatiana H, Mao Lu, McCormick Timothy, Cui Min, Lee Fred T, Ziemlewicz Timothy J

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the efficacy of high-frequency jet ventilation (HFJV) to reduce the effects of respiratory motion on the resultant treatment zone during hepatic histotripsy in an in vivo porcine model.

MATERIALS AND

METHODS

Non-tumor bearing swine (n = 6, 50.1 kg) underwent hepatic histotripsy with both HFJV and conventional ventilation (CV) in separate locations. Treatments were followed by contrast-enhanced magnetic resonance imaging (MRI) and necropsy. Treatment zone size (with emphasis on the cranial-caudal (CC) dimension), volume, and a survey for complications were conducted by MRI and at necropsy. Histopathology was performed to confirm complete cell kill in the treatment zone. Treatment precision was assessed by the width of the transition zone (TZ, zone of partial treatment) with a narrower TZ denoting increased precision.

RESULTS

Animals tolerated treatments with no adverse events. Treatment zones created during HFJV were less elongated than during CV (CC dimension during HFJV = 27.8 mm vs. CV = 32.3 mm, p = 0.04). Mean TZ width (treatment precision) was narrower in the HFJV group (HFJV = 4.1 mm, CV = 6.9 mm, p < 0.001), particularly at the cranial margin (HFJV = 4.0 mm, CV = 8.2, p = 0.018). Off-target treatments occurred in the chest wall (n = 2) and spleen (n = 1).

CONCLUSION

High-frequency jet ventilation reduces the craniocaudal elongation of histotripsy treatment zones caused by respiratory motion and improves the precision of histotripsy compared to conventional ventilation in this animal model.

Для цитирования: Winterholler J Erik, Kisting Meridith A, Falk Katrina L, Kisting Adrienne L, Jentink Madeline S, White Jim K, Lubner Meghan G, Laeseke Paul F, Knavel Koepsel Erica M, Swietlik John F, Hinshaw J Louis, Ferreira Tatiana H, Mao Lu, McCormick Timothy, Cui Min, Lee Fred T, Ziemlewicz Timothy J. Hepatic Histotripsy: Jet Ventilation Decreases the Effect of Respiratory Motion in A Porcine Liver Model.. Cardiovascular and interventional radiology. 2025. DOI: 10.1007/s00270-025-04060-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.