MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/id.0000000000000363

Медицинская библиотека · Implant dentistry · 2016

Quantitative Kinetics Evaluation of Blocks Versus Granules of Biphasic Calcium Phosphate Scaffolds (HA/β-TCP 30/70) by Synchrotron Radiation X-ray Microtomography: A Human Study.

Giuliani Alessandra, Manescu Adrian, Mohammadi Sara, Mazzoni Serena, Piattelli Adriano, Mangano Francesco, Iezzi Giovanna, Mangano Carlo

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

Successful bone regeneration using both granules and blocks of biphasic calcium phosphate materials has been reported in the recent literature, in some clinical applications for maxillary sinus elevation, but the long-term kinetics of bone regeneration has still not been fully investigated.

MATERIALS AND

METHODS

Twenty-four bilateral sinus augmentation procedures were performed and grafted with hydroxyapatite/β-tricalcium phosphate 30/70, 12 with granules and 12 with blocks. The samples were retrieved at different time points and were evaluated for bone regeneration, graft resorption, neovascularization, and morphometric parameters by computed microtomography and histology.

RESULTS

A large amount of newly formed bone was detected in the retrieved specimens, together with a good rate of biomaterial resorption and the formation of a homogeneous and rich net of new vessels. The morphometric values were comparable at 5/6 months from grafting but, 9 months after grafting, revealed that the block-based specimens mimicked slightly better than granule-based samples the healthy native bone of the maxillary site.

CONCLUSION

The scaffold morphology was confirmed to influence the long-term kinetics of bone regeneration.

Для цитирования: Giuliani Alessandra, Manescu Adrian, Mohammadi Sara, Mazzoni Serena, Piattelli Adriano, Mangano Francesco, Iezzi Giovanna, Mangano Carlo. Quantitative Kinetics Evaluation of Blocks Versus Granules of Biphasic Calcium Phosphate Scaffolds (HA/β-TCP 30/70) by Synchrotron Radiation X-ray Microtomography: A Human Study.. Implant dentistry. 2016. DOI: 10.1097/id.0000000000000363.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.