Comparing intermediate-term hearing results of NiTiBOND and Nitinol prostheses in stapes surgery.
Аннотация
OBJECTIVE
To statistically analyse the hearing thresholds of two cohorts undergoing stapedotomy for otosclerosis with two different prostheses.
METHOD: A retrospective study was conducted comparing NiTiBOND (n = 53) and Nitinol (n = 38) prostheses.
RESULTS
Average follow-up duration was 4.1 years for NiTiBOND and 4.4 years for Nitinol prostheses. The post-operative air-bone gap was 10 dB or less, indicating clinical success. The p-values for differences between (1) pre- and post-operative values in the NiTiBOND group, (2) pre- and post-operative values in the Nitinol group, (3) pre-operative values and (4) post-operative values in the two groups were: air-bone gap - p < 0.001, p < 0.001, p = 0.631 and p = 0.647; four-frequency bone conduction threshold - p = 0.076, p = 0.129, p < 0.001 and p = 0.005; four-frequency air conduction threshold - p < 0.001, p < 0.001, p = 0.043 and p = 0.041; three-frequency (1, 2 and 4 kHz) bone conduction threshold pre-operatively - p = 0.639, p = 0.495, p = 0.001 and p = 0.01; and air conduction threshold at 4 kHz: - p < 0.001, p < 0.001, p = 0.03 and p = 0.058.
CONCLUSION
Post-operative audiological outcomes for NiTiBOND and Nitinol were comparable.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.