Clinical implant dentistry and related research · 2015
Follow-Up of the Sinus Membrane Elevation Technique for Maxillary Sinus Implants without the Use of Graft Material.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Riben Christopher, Thor Andreas
Аннотация
BACKGROUND: There is a limited amount of studies evaluating long-term results of the sinus membrane elevation technique for bone formation around implants in the maxillary sinus floor without the use of bone graft material.
PURPOSE: To investigate the long-term results of this technique with regard to implant survival and bone gain in the maxillary sinus floor.
MATERIALS AND METHODS: A retrospective study was conducted on patients who had undergone the surgical procedure from November 2001 to August 2008. Thirty-six patients with a total of 87 implants (ASTRA TECH Implant System™) in 53 sinuses were examined. After a submerged healing period of 6 months and at least 12 months of loading, the patients were examined clinically and radiologically. Implant stability was measured using resonance frequency analysis (RFA).
RESULTS: The mean follow-up time was 4.6 years (range 1.5-7 years). Five implants were lost giving a survival rate of 94.3%.Subantral preoperative vertical bone levels were in the range of 1 to 10 mm. The average bone gain at the sinus floor was 6 mm. The 55 fixtures eligible for RFA displayed a mean implant stability quotient of 77 (range 56-85.5).
CONCLUSION: The present study illustrates the long-term reliability of the technique.
PURPOSE: To investigate the long-term results of this technique with regard to implant survival and bone gain in the maxillary sinus floor.
MATERIALS AND METHODS: A retrospective study was conducted on patients who had undergone the surgical procedure from November 2001 to August 2008. Thirty-six patients with a total of 87 implants (ASTRA TECH Implant System™) in 53 sinuses were examined. After a submerged healing period of 6 months and at least 12 months of loading, the patients were examined clinically and radiologically. Implant stability was measured using resonance frequency analysis (RFA).
RESULTS: The mean follow-up time was 4.6 years (range 1.5-7 years). Five implants were lost giving a survival rate of 94.3%.Subantral preoperative vertical bone levels were in the range of 1 to 10 mm. The average bone gain at the sinus floor was 6 mm. The 55 fixtures eligible for RFA displayed a mean implant stability quotient of 77 (range 56-85.5).
CONCLUSION: The present study illustrates the long-term reliability of the technique.