Visual performance of an EDOF intraocular lens in patients with low to moderate irregular astigmatism.

Danzinger Victor, Lisy Marcus, Mahnert Nikolaus, Schranz Markus, Abela-Formanek Claudette, Leydolt Christina, Schartmüller Daniel

СтатьяКлиническое исследованиеПеревод в очереди

Аннотация

PURPOSE: To assess visual and subjective outcomes in eyes with low to moderate irregular astigmatism following extended-depth-of-focus (EDOF) intraocular lens (IOL) implantation.

SETTING

Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria.

DESIGN

Single-center, prospective, clinical trial.

METHODS

This study assessed patients with low to moderate irregular astigmatism who received bilateral cataract surgery using the nontoric/toric AcrySof IQ Vivity IOL. At the 4-month examination, monocular and binocular corrected distance visual acuity (CDVA) and distance-corrected intermediate visual acuity (DCIVA), monocular 25% low-contrast CDVA and DCIVA, monocular distance-corrected near visual acuity (DCNVA) and corrected near visual acuity (CNVA), monocular defocus curve from +0.5 to -2.5 diopters (D), wavefront aberrometry, and subjective outcome (VF-7) were evaluated.

RESULTS

28 patients presenting low to moderate irregular astigmatism with mean 1.27 ± 0.83 D cylinder and 0.04 ± 0.01 μm/mm 2 root mean square per area were analyzed. At the follow-up visit, mean logMAR results were the following: Monocular CDVA was -0.01 ± 0.08, binocular CDVA was -0.08 ± 0.07, monocular DCIVA was 0.18 ± 0.11, binocular DCIVA was 0.08 ± 0.08, monocular 5% low-contrast CDVA was 0.40 ± 0.12, DCIVA was 0.38 ± 0.11, monocular DCNVA was 0.38 ± 0.09, and CNVA was 0.09 ± 0.09. Monocular defocus curves demonstrated 0.16 ± 0.09 logMAR at -1.5 D of defocus and ≤0.2 logMAR visual acuity up to -1.66 D of defocus. Difficulties during daily life activities (VF-7 questionnaire) were low.

CONCLUSIONS

In eyes with low to moderate irregular astigmatism, the AcrySof IQ Vivity IOL provided very good monocular and binocular visual performance at far and intermediate distance after bilateral cataract surgery. These findings suggest that low to moderate irregular astigmatism does not substantially decrease visual outcome following bilateral EDOF IOL implantation.

Для цитирования: Danzinger Victor, Lisy Marcus, Mahnert Nikolaus, Schranz Markus, Abela-Formanek Claudette, Leydolt Christina, Schartmüller Daniel. Visual performance of an EDOF intraocular lens in patients with low to moderate irregular astigmatism.. Journal of cataract and refractive surgery. 2026. DOI: 10.1097/j.jcrs.0000000000001862.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.