MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00066-006-1530-z

Медицинская библиотека · Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2006

Health-related quality of life after permanent interstitial brachytherapy for prostate cancer: correlation with postimplant CT scan parameters.

Pinkawa Michael, Fischedick Karin, Piroth Marc D, Gagel Bernd, Borchers Holger, Jakse Gerhard, Eble Michael J

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine dosimetric risk factors for increased toxicity after permanent interstitial brachytherapy for prostate cancer.

PATIENTS AND

METHODS

Quality of life questionnaires (Expanded Prostate Cancer Index Composite) of 60 and 56 patients were analyzed after a median posttreatment time of 6 weeks (A-acute) and 16 months (L-late). The corresponding CT scans were performed 30 days after the implant. The prostate, rectal wall, and base of seminal vesicles were contoured. Prostate volume, number of seeds and needles as well as dosimetric parameters were correlated with the morbidity scores.

RESULTS

For a prostate volume of 38 +/- 12 cm(3) (mean +/- standard deviation), 54 +/- 7 (125)I sources (Rapid Strands), activity of 22.6 +/- 3.0 MBq [0.61 +/- 0.08 mCi]) were implanted using 20 +/- 6 needles. Improved late urinary function scores resulted from a higher number of sources per cm(3) (> or = 1.35). A prostate D(90) < 170 Gy (A)/< 185 Gy (L) and base of seminal vesicle D(10) < 190 Gy (A and L) were associated with higher urinary function scores. Late rectal function scores were significantly higher for patients with a prostate V(200) < 50% and V(150) < 75%. Patients with a prostate volume < 40 cm(3) reached better sexual function scores (A and L). A higher number of needles per cm(3) (> or = 0.5) resulted in improved late urinary, bowel and sexual function scores.

CONCLUSION

Quality of life after a permanent implant can be improved by using an adequate amount of sources and needles. With an increasing number of seeds per cm(3), dose homogeneity is improving. A prostate D(90) < 170 Gy and a base of seminal vesicle D(10) < 190 Gy (as an indicator of the dose to the bladder neck and urethral sphincter) can be recommended to maintain a satisfactory urinary function.

Для цитирования: Pinkawa Michael, Fischedick Karin, Piroth Marc D, Gagel Bernd, Borchers Holger, Jakse Gerhard, Eble Michael J. Health-related quality of life after permanent interstitial brachytherapy for prostate cancer: correlation with postimplant CT scan parameters.. Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]. 2006. DOI: 10.1007/s00066-006-1530-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.