MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.urology.2005.12.022

Медицинская библиотека · Urology · 2006

Evaluation of a novel knotless self-anchoring suture material for urinary tract reconstruction.

Weld Kyle J, Ames Caroline D, Hruby Greg, Humphrey Peter A, Landman Jaime

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To evaluate a novel prototype self-anchoring suture (SAS) material that incorporates unidirectional "barbs" designed to grip and approximate tissue without the need for suture ligation for urinary tract reconstructive procedures.

METHODS

The in vitro failure strength of various porcine tissue approximations with SAS was compared with the strength of similar approximations with standard ligated suture. For in vivo analysis, 3 pigs underwent laparoscopic pyeloplasty with SAS on one side and 2-0 Vicryl suture on the contralateral side. Nine pigs underwent bladder neck anastomoses (BNA) performed with SAS (n = 3) and standard ligated interrupted suturing (n = 3) or standard ligated running suturing (n = 3). The operative times were compared. One week after surgery, the integrity of each anastomosis was evaluated radiographically and histopathologically.

RESULTS

The in vitro analysis revealed no statistically different (P = 0.22) failure forces between the approximations performed with SAS (13.2 +/- 2.6 N) and standard suture (14.1 +/- 3.1 N). The in vitro analysis revealed no difference in operative times for the pyeloplasties (P = 0.72) or BNA (P = 0.31). None of the 1-week postoperative radiographic studies revealed extravasation. The histopathologic analysis revealed more fibrotic reaction associated with the SAS BNA procedures (P <0.01).

CONCLUSIONS

Self-anchoring suture secures tissue approximations at loads equivalent to tissue approximations with standard tied suture. Self-anchoring suture obviates the need for knot tying and provides a watertight anastomosis. With laparoscopic knot tying experience, anastomotic time with SAS and standard suture do not differ. Self-anchoring suture might induce more fibrosis. Long-term follow-up evaluation will be required before clinical application.

Для цитирования: Weld Kyle J, Ames Caroline D, Hruby Greg, Humphrey Peter A, Landman Jaime. Evaluation of a novel knotless self-anchoring suture material for urinary tract reconstruction.. Urology. 2006. DOI: 10.1016/j.urology.2005.12.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.