MedElevator Войти в исследования
← Поиск публикаций

DOI 10.11477/mf.1436204131

Медицинская библиотека · No shinkei geka. Neurological surgery · 2020

[A Case of Ruptured Arteriovenous Malformation Successfully Treated with Target Embolization for Pseudoaneurysm Detected Using Chronological Three-dimensional Digital Subtraction Angiography Fusion Images].

Murai Satoshi, Sugiu Kenji, Hishikawa Tomohito, Hiramatsu Masafumi, Nishihiro Shingo, Kidani Naoya, Takahashi Yu, Date Isao

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

We herein report a case of ruptured arterio-venous malformation(AVM)detected using three-dimensional digital subtraction angiography(3DDSA)fusion images and successfully treated with target embolization for pseudoaneurysm. A 50-year-old man with a history of AVM was admitted to our department for the treatment of ruptured high-grade AVM in the right parietal lobe. Although a bleeding point was not evident on DSA, the patient had re-rupture in the right ventricle, one month after admission. Chronological 3DDSA fusion images generated from 3DDSA images taken on admission and after re-rupture revealed a newly visualized intranidal pseudoaneurysm near a hematoma. Contrast-enhanced magnetic resonance imaging showed vessel wall enhancement along the posterior horn of the right ventricle;this enhancement corresponded to the location of the pseudoaneurysm. We planned target embolization for the intranidal pseudoaneurysm to prevent re-bleeding. The origin of the feeder was so steep that a microcatheter could not be advanced deeply, and embolization with 20% n-butyl-2-cyanoacrylate resulted in proximal occlusion. Follow-up angiography 1 week after embolization showed complete disappearance of the pseudoaneurysm, and the patient had no recurrence of aneurysm until one year.

Для цитирования: Murai Satoshi, Sugiu Kenji, Hishikawa Tomohito, Hiramatsu Masafumi, Nishihiro Shingo, Kidani Naoya, Takahashi Yu, Date Isao. [A Case of Ruptured Arteriovenous Malformation Successfully Treated with Target Embolization for Pseudoaneurysm Detected Using Chronological Three-dimensional Digital Subtraction Angiography Fusion Images].. No shinkei geka. Neurological surgery. 2020. DOI: 10.11477/mf.1436204131.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.