MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmr.2010.06.006

Медицинская библиотека · Journal of magnetic resonance (San Diego, Calif. : 1997) · 2010

In vivo 1H NMR spectroscopy of the human brain at 9.4 T: initial results.

Deelchand Dinesh Kumar, Van de Moortele Pierre-François, Adriany Gregor, Iltis Isabelle, Andersen Peter, Strupp John P, Vaughan J Thomas, Uğurbil Kâmil, Henry Pierre-Gilles

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

In vivo proton NMR spectroscopy allows non-invasive detection and quantification of a wide range of biochemical compounds in the brain. Higher field strength is generally considered advantageous for spectroscopy due to increased signal-to-noise and increased spectral dispersion. So far (1)H NMR spectra have been reported in the human brain up to 7 T. In this study we show that excellent quality short echo time STEAM and LASER (1)H NMR spectra can be measured in the human brain at 9.4 T. The information content of the human brain spectra appears very similar to that measured in the past decade in rodent brains at the same field strength, in spite of broader linewidth in human brain. Compared to lower fields, the T(1) relaxation times of metabolites were slightly longer while T(2) relaxation values of metabolites were shorter (<100 ms) at 9.4 T. The linewidth of the total creatine (tCr) resonance at 3.03 ppm increased linearly with magnetic field (1.35 Hz/T from 1.5 T to 9.4 T), with a minimum achievable tCr linewidth of around 12.5 Hz at 9.4 T. At very high field, B(0) microsusceptibility effects are the main contributor to the minimum achievable linewidth.

Для цитирования: Deelchand Dinesh Kumar, Van de Moortele Pierre-François, Adriany Gregor, Iltis Isabelle, Andersen Peter, Strupp John P, Vaughan J Thomas, Uğurbil Kâmil, Henry Pierre-Gilles. In vivo 1H NMR spectroscopy of the human brain at 9.4 T: initial results.. Journal of magnetic resonance (San Diego, Calif. : 1997). 2010. DOI: 10.1016/j.jmr.2010.06.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.