MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3760/cma.j.issn.1001-9391.2019.12.002

Медицинская библиотека · Zhonghua lao dong wei sheng zhi ye bing za zhi = Zhonghua laodong weisheng zhiyebing zazhi = Chinese journal of industrial hygiene and occupational diseases · 2019

[Characteristics of auditory brainstom response and auditory steady state evoked responses in noise-induced hearing loss population].

Zhang J B, Liu J, Ma G F, Sun D Y

СтатьяПеревод пока не подготовлен

Аннотация

Objective

To explore the characteristics of auditory steady state evoked responses (ASSR) and auditory brainstem response (ABR) in noise-induced hearing loss population and the relationship between the response threshold of corresponding frequency and pure tone audiometry (PTA) .

Methods

Noise-induced hearing loss patients who completed subjective and objective audiometry in our hospital from October 2014 to October 2018 were collected. The results of PTA, ABR, ASSR and the correlation between subjective and objective audiometry were discussed.

Results

A total of 381 ears of 193 patients were enrolled. The difference of 0.5, 1.0, 2.0 and 4.0 kHz between ASSR threshold and PTA was 5.9, 6.9, 11.8 and 1.8 dB, respectively. The correlation coefficients were 0.638, 0.680, 0.657 and 0.608. The difference of 1.0, 2.0, 3.0 and 4.0 kHz between ABR threshold and PTA was 44.2, 35.0, 19.0 and 2.0 dB. With the increase of frequency, the threshold difference between ABRt V wave and PTA decreased gradually.

Conclusion

ASSR and ABR response thresholds are valuable in subjective assessment on noise-induced hearing loss. The thresholds of ASSR and ABR at 4 kHz are close to those of PTA.

Для цитирования: Zhang J B, Liu J, Ma G F, Sun D Y. [Characteristics of auditory brainstom response and auditory steady state evoked responses in noise-induced hearing loss population].. Zhonghua lao dong wei sheng zhi ye bing za zhi = Zhonghua laodong weisheng zhiyebing zazhi = Chinese journal of industrial hygiene and occupational diseases. 2019. DOI: 10.3760/cma.j.issn.1001-9391.2019.12.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.