DOI 10.1016/j.diii.2024.09.008
Deep learning reconstruction for accelerated high-resolution upper abdominal MRI improves lesion detection without time penalty.
Аннотация
PURPOSE: The purpose of this study was to compare a conventional T1-weighted volumetric interpolated breath-hold examination (VIBE) sequence with a DL-reconstructed accelerated high-resolution VIBE sequence (HR-VIBEDL) in terms of image quality, lesion conspicuity, and lesion detection.
MATERIALS AND
METHODS
Consecutive patients referred for upper abdominal MRI between December 2023 and March 2024 at a single tertiary center were prospectively enrolled. Participants underwent 1.5 T upper abdominal MRI with acquisition of spectrally fat-saturated unenhanced and gadobutrol-enhanced conventional VIBE (fourfold acceleration, 3.0 mm slice thickness, 72 axial slices) and HR-VIBEDL (sixfold acceleration, 2.0 mm, 108 slices). Both sequences had an identical acquisition time of 16 s. Image analysis was performed by three readers in a blinded and randomized fashion, with respect to image quality, lesion conspicuity, and lesion detection in liver, pancreas, spleen, lymph nodes and adrenal glands. Image quality parameters were compared using repeated measures analysis of variance. Lesion detection rates were compared using Fisher exact test. Inter-reader agreement was assessed using Fleiss κ test.
RESULTS
Among 744 consecutive patients, 50 participants were evaluated. There were 30 men and 20 women, with a mean age of 60 ± 15 (standard deviation [SD]) years (age range: 18-88 years). HR-VIBEDL images demonstrated superior signal-to-noise ration and edge sharpness by comparison with conventional VIBE images (P < 0.001 for both), with substantial interreader agreement (κ: 0.70-0.90). Lesion conspicuity was higher with for HR-VIBEDL images (3.50 ± 0.83 [SD]) by comparison with conventional VIBE images (3.21 ± 0.98 [SD]) (P = 0.005). There were 171 upper abdominal lesions, yielding a total of 513 for all three readers. HR-VIBEDL images yielded higher lesion detection rate (97.5 %; 500/513) compared to conventional VIBE images (93.2 %; 478/513) (P = 0.002).
CONCLUSION
HR-VIBEDL images of the upper abdomen result in superior image quality, better lesion conspicuity, and improved lesion detection without time penalty by comparsion with conventional VIBE images.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.