MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tcyb.2025.3555104

Медицинская библиотека · IEEE transactions on cybernetics · 2025

Neuroadaptive Admittance Control for Human-Robot Interaction With Human Motion Intention Estimation and Output Error Constraint.

Liu Chengguo, Zhao Kai, Si Weiyong, Li Junyang, Yang Chenguang

СтатьяПеревод пока не подготовлен

Аннотация

Human-robot interaction (HRI) is a crucial component in the field of robotics, and enabling faster response, higher accuracy, as well as smaller human effort, is essential to improve the efficiency, robustness, and applicability of HRI-driven tasks. In this article, we develop a novel neuroadaptive admittance control with human motion intention (HMI) estimation and output error constraint for natural and stable interaction. First, the interaction force information of the robot is utilized to predict the HMI and the stiffness in the admittance model is dynamically updated based on surface electromyography (sEMG) signals of the human upper limb to achieve human-like compliance. Then, based on the designed error transformation mechanism, an innovative prescribed performance control (PPC) is proposed that allows the trajectory error to converge to the given constraint range within a predefined time for any bounded initial conditions, thus enabling the robot to maintain a comprehensive performance of moving in the desired direction as guided by the human. Also, an adaptive neural network (NN) is employed to compensate for the uncertainty of robotics systems to improve the tracking accuracy further. According to the Lyapunov stability analysis criterion, our approach ensures that all states of the closed-loop system remain globally uniformly ultimately bounded. Finally, a series of real-world robot experiments demonstrate the effectiveness of the proposed framework.

Для цитирования: Liu Chengguo, Zhao Kai, Si Weiyong, Li Junyang, Yang Chenguang. Neuroadaptive Admittance Control for Human-Robot Interaction With Human Motion Intention Estimation and Output Error Constraint.. IEEE transactions on cybernetics. 2025. DOI: 10.1109/tcyb.2025.3555104.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.