BACKGROUND

Access to timely and accurate diagnostic imaging is essential for high-quality healthcare. Point-of-care ultrasound has been shown to be accessible and effective in many aspects of healthcare, including assessing changes in lung pathology. However, few studies have examined self-administered at-home lung ultrasound (SAAH-LUS), in particular performed by non-clinical patients (NCPs).

RESEARCH QUESTION: Are NCPs able to perform SAAH-LUS using remote teleguidance and produce interpretable images?

STUDY

DESIGN

Patients were enrolled to the study in a mix of in-person and virtual recruitment, and shipped a smartphone as well as a point of care ultrasound device. Tele-guidance was provided by a remote physician using software integrated with the point of care ultrasound device, allowing real-time remote visualization and guidance of a patient scanning their own chest. A post-intervention survey was conducted to assess patient satisfaction, feasibility, and acceptability of SAAH-LUS. Two POCUS expert reviewers reviewed the scans for interpretability, and inter-rater agreement between the two reviewers was also computed.

RESULTS

Eighteen patients successfully underwent 7-14 days of daily telemedicine in parallel to daily SAAH-LUS. Across 1339 scans obtained from ten different lung zones, the average proportion of interpretability was 96% with a chance-corrected agreement, or Cohen's kappa, reported as κ = 0.67 (significant agreement). 100% of NCPs surveyed found SAAH-LUS to be a positive experience, particularly for its ease of operation and ability to increase access to healthcare services.

INTERPRETATION: This study demonstrates that NCPs can obtain interpretable LUS images at home, highlighting the potential for SAAH-LUS to increase diagnostic capacity, particularly for rural and remote regions where complex imaging and healthcare providers are difficult to obtain. Trial registration The clinical trials has been registered (clinicaltrials.gov).

REGISTRATION NUMBER: NCT04967729.

Для цитирования: Elmi Nika, Sadri Yasmin, Myslik Frank, Chenkin Jordan, Cherniak William. Self-administered at-home lung ultrasound with remote guidance in patients without clinical training.. Respiratory research. 2024. DOI: 10.1186/s12931-024-02744-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.