MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/annonc/mdl425

Медицинская библиотека · Annals of oncology : official journal of the European Society for Medical Oncology · 2006

A comparative study on the value of FDG-PET and sentinel node biopsy to identify occult axillary metastases.

Veronesi U, De Cicco C, Galimberti V E, Fernandez J R, Rotmensz N, Viale G, Spano G, Luini A, Intra M, Veronesi P, Berrettini A, Paganelli G

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Sentinel node biopsy (SNB) has become a standard treatment in staging axillary lymph nodes in early breast cancer. SNB, however, is an invasive procedure and is time-consuming when the sentinel node is analysed intra-operatively. Breast cancer is frequently characterised by increased 2-fluoro-2-deoxy-D-glucose uptake and many studies have shown encouraging results in detecting axillary lymph node metastases. The aim of this study was to compare SNB and -positron emission tomography (-PET) imaging, to assess their values in detecting occult axillary metastases.

PATIENTS AND

METHODS

In all, 236 patients with breast cancer and clinically negative axilla were enrolled in the study. 18-FDG-PET was carried out before surgery, using a positron emission tomography (PET)/computed tomography scanner. In all patients, SNB was carried out after identification through lymphoscintigraphy. Patients underwent axillary lymph nodes dissection (ALND) in cases of positive FDG-PET or positive SNB. The results of PET scan were compared with histopathology of SNB and ALND.

RESULTS

In all, 103 out of the 236 patients (44%) had metastases in axillary nodes. Sensitivity of FDG-PET scan for detection of axillary lymph node metastases in this series was low (37%); however, specificity and positive predictive values were acceptable (96% and 88%, respectively).

CONCLUSIONS

The high specificity of PET imaging indicates that patients who have a PET-positive axilla should have an ALND rather than an SNB for axillary staging. In contrast, FDG-PET showed poor sensitivity in the detection of axillary metastases, confirming the need for SNB in cases where PET is negative in the axilla.

Для цитирования: Veronesi U, De Cicco C, Galimberti V E, Fernandez J R, Rotmensz N, Viale G, Spano G, Luini A, Intra M, Veronesi P, Berrettini A, Paganelli G. A comparative study on the value of FDG-PET and sentinel node biopsy to identify occult axillary metastases.. Annals of oncology : official journal of the European Society for Medical Oncology. 2006. DOI: 10.1093/annonc/mdl425.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.