Idealized aortic annuloplasty FSI digital twin of 3D-printed phantoms with 4D-flow MRI comparison.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bontempi Luca, Zattoni Marta, Ramella Anna, Migliavacca Francesco, Ringgaard Steffen, Kim Won Yong, Johansen Peter, Colombo Monika

Аннотация

BACKGROUND: Aortic annuloplasty, involving the implantation of an external ring around the aortic root to reduce annular dimensions, is a promising treatment for aortic valve insufficiency. However, its hemodynamic effects remain underexplored due to the absence of computational models validated by experimental and clinical data.

METHODS: This study introduces a computational fluid-structure interaction (FSI) model of supra valvular aortic annuloplasty using 4D-flow magnetic resonance imaging (MRI). Native and post-annuloplasty conditions of idealized aortic root phantoms, including the aortic valve, were CAD-modelled and 3D-printed with elastic resin. These phantoms were tested in a mock circulatory flow-loop providing normal pulsatile physiologic conditions using a glycerol-water mixture to simulate blood viscosity. Flow and pressure data collected from sensors were used as boundary conditions for FSI simulations. Experimental velocity fields from 4D-flow MRI were compared to computational results to assess model accuracy.

RESULTS: MRI scans of the annuloplasty model showed an increased peak systolic velocity (up to 145.4 cm/s) and localized flow alterations, corresponding to a higher pressure gradient across the valve. During regurgitation, the annuloplasty model showed broader velocity distributions compared to the native condition. The FSI simulations closely matched 4D-flow MRI data, with strong correlation coefficients (r > 0.93) and minimal Bland-Altman differences, particularly during systolic phases.

CONCLUSIONS: This study establishes an integrative methodology combining in-vitro, in-silico, and clinical imaging techniques to evaluate aortic annuloplasty hemodynamics. The in-vitro validated digital twin framework offers a pathway for patient-specific modelling, enabling prediction of surgical outcomes and optimization of aortic valve repair strategies.