MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10549-006-9192-1

Медицинская библиотека · Breast cancer research and treatment · 2006

Factors affecting failed localisation and false-negative rates of sentinel node biopsy in breast cancer--results of the ALMANAC validation phase.

Goyal Amit, Newcombe Robert G, Chhabra Alok, Mansel Robert E, ALMANAC Trialists Group

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Despite the widespread application of sentinel lymph node biopsy (SLNB) for early stage breast cancer, there is a wide variation in reported test performance characteristics. A major aim of this prospective multicentre validation study was to quantify detection and false-negative rates of SLNB and evaluate factors influencing them.

METHODS

Eight-hundred and fourty-two patients with clinically node-negative breast cancer underwent SLNB according to a standardised protocol that used a combination of radiopharmaceutical 99mTc-albumin colloid and Patent Blue V dye. SLNB was followed by standard axillary treatment at the same operation in all patients.

RESULTS

Sentinel lymph nodes (SLNs) were identified in 803 (96.1%) of 836 evaluable cases. The median number of SLNs removed per patient was 2 (range 1-9). There were 19 false negatives, resulting in a sensitivity of 263/282 (93.3%) and accuracy 782/803 (97.6%). SLNs were successfully identified by blue dye in 698 (85.6%), by isotope in 698 (85.6%), and by the combination of blue dye and isotope in 782 (96.0%) of 815 patients. Among 276 node positive patients, one or more positive SLNs were identified by blue dye in 251 (90.9%), by isotope in 246 (89.1%) and by the combination of blue dye and gamma probe in 258 (93.5%). Obesity, tumor location other than upper outer quadrant and non-visualisation of SLNs on the pre-operative lymphoscintiscan were significantly associated with failed localisation (p<0.001, p=0.008, p<0.001, respectively). The false-negative rate in patients with grade 3 tumors was 9.6%, compared with 4.7% in those with grade 2 tumors (p=0.022). The false-negative rate in patients who had one SLN harvested was 10.1%, compared with 1.1% in those who had multiple SLNs (three or more) removed (p=0.010).

CONCLUSION

SLNB can accurately determine whether axillary metastases are present in patients with early stage breast cancer with clinically negative axillary nodes. Both success and accuracy of SLNB are optimised by the combined use of blue dye and isotope. SLNB success decreases with increasing body mass, tumor location other than the upper outer quadrant and non-visualisation of hot nodes on the pre-operative lymphoscintiscan. This study demonstrates reduction in the predictive value of a negative SLNB in grade 3 tumors.

Для цитирования: Goyal Amit, Newcombe Robert G, Chhabra Alok, Mansel Robert E, ALMANAC Trialists Group. Factors affecting failed localisation and false-negative rates of sentinel node biopsy in breast cancer--results of the ALMANAC validation phase.. Breast cancer research and treatment. 2006. DOI: 10.1007/s10549-006-9192-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.