Fatal false-negative transfusion infection involving a buffy coat platelet pool contaminated with biofilm-positive Staphylococcus epidermidis: a case report.
Клинический случайСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kou Yuntong, Pagotto Franco, Hannach Barbara, Ramirez-Arcos Sandra
Аннотация
BACKGROUND: Bacterial contamination of platelet concentrates (PCs) poses the major posttransfusion infectious risk in developed countries. The aerobic microorganism most frequently isolated from PCs is coagulase-negative Staphylococcus epidermidis, a normal inhabitant of the human skin, which has been involved in fatal transfusion reactions worldwide.
CASE REPORT: In September 2014, a splenectomized elderly male patient, suffering from leukemia, was transfused with two 5-day-old buffy coat platelet (PLT) pools. The patient returned to emergency on the same day with a low-grade fever. He was bacteremic and died on the next day. Microbiology and molecular testing of a blood sample from the patient and one of the PCs yielded the same S. epidermidis strain. Further analysis demonstrated that this S. epidermidis isolate displays a biofilm-positive phenotype in PCs.
DISCUSSION: At Canadian Blood Services, PCs are screened for bacterial contamination with the BacT/ALERT system (bioMérieux) at approximately 24 hours postcollection. The implicated PC had been tested and yielded a false-negative culture result. A titration experiment indicated that, at the time of screening, the contaminated PC had a titer of less than 0.74 colony-forming units (CFU)/mL (<227 CFUs/unit) of S. epidermidis. Mathematical models have predicted that up to 70% of PCs contaminated with coagulase-negative staphylococci at concentrations of 0.02 CFU/mL can be missed by BacT/ALERT screening.
CONCLUSION: Despite several mitigation strategies, false-negative cultures with current PLT screening practices still occur. This report creates awareness of the pathogenicity of opportunistic S. epidermidis, a low-virulence organism, in susceptible patients who may not develop a typical transfusion reaction.
CASE REPORT: In September 2014, a splenectomized elderly male patient, suffering from leukemia, was transfused with two 5-day-old buffy coat platelet (PLT) pools. The patient returned to emergency on the same day with a low-grade fever. He was bacteremic and died on the next day. Microbiology and molecular testing of a blood sample from the patient and one of the PCs yielded the same S. epidermidis strain. Further analysis demonstrated that this S. epidermidis isolate displays a biofilm-positive phenotype in PCs.
DISCUSSION: At Canadian Blood Services, PCs are screened for bacterial contamination with the BacT/ALERT system (bioMérieux) at approximately 24 hours postcollection. The implicated PC had been tested and yielded a false-negative culture result. A titration experiment indicated that, at the time of screening, the contaminated PC had a titer of less than 0.74 colony-forming units (CFU)/mL (<227 CFUs/unit) of S. epidermidis. Mathematical models have predicted that up to 70% of PCs contaminated with coagulase-negative staphylococci at concentrations of 0.02 CFU/mL can be missed by BacT/ALERT screening.
CONCLUSION: Despite several mitigation strategies, false-negative cultures with current PLT screening practices still occur. This report creates awareness of the pathogenicity of opportunistic S. epidermidis, a low-virulence organism, in susceptible patients who may not develop a typical transfusion reaction.