m+Medelevator.RU
← Поиск публикаций
European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026

Determining ideal electrode insertion depth in paediatric cochlear implantation.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rami Mohammed, Lakhdar Youssef, Chehbouni Mohamed, Oulghoul Omar, Orche Aimen El, Ifguis Ousama, Rochdi Youssef, Raji Abdelaziz

Аннотация

BACKGROUND: Speech and language outcomes following early cochlear implantation vary widely among patients. Identifying modifiable, device-specific surgical parameters contributing to this variability is essential to optimise therapeutic outcomes.

OBJECTIVE: This study investigates the association between electrode angular depth of insertion (aDOI) and speech perception outcomes in a homogeneous cohort of children implanted with a single lateral wall electrode design.

METHODS: A cohort of 25 prelingually deaf children, aged 4 to 5 years at implantation, received unilateral Oticon Neuro ZTI cochlear implants at Mohammed VI University Hospital in Marrakech. All subjects had idiopathic deafness, completed at least two years of speech therapy, and demonstrated successful electrode activation. Postoperative modified Stenvers-view radiographs were used to calculate angular depth of insertion (aDOI). Auditory outcomes were assessed using APCEI and CAP scores. Response surface regression modelling was employed to explore the non-linear relationship between aDOI and auditory performance and to estimate the device-specific angular depth associated with peak predicted outcomes.

RESULTS: The mean angular depth of insertion was 275°. APCEI scores ranged from 11 to 21, and CAP scores from 3 to 7. Non-linear modelling identified a predicted peak in auditory performance at approximately 340°, corresponding to an APCEI score of 17.67 and CAP score of 5.98. This value represents the model-derived optimum within the observed insertion range for the Oticon Neuro ZTI electrode platform.

CONCLUSION: Within this homogeneous cohort implanted with a single lateral wall electrode design, auditory outcomes demonstrated a non-linear association with angular depth of insertion, with peak predicted performance near 340°. These findings highlight the importance of device-specific insertion strategies and careful surgical planning. The results should not be generalized to other electrode designs without dedicated validation.