MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jmri.25096

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2015

Feasibility study of using intravoxel incoherent motion mri to detect parotid gland abnormalities in early-stage Sjögren syndrome patients.

Su Guo-Yi, Xu Xiao-Quan, Wang Yan-Yan, Hu Hao, Shen Jie, Hong Xun-Ning, Shi Hai-Bin, Wu Fei-Yun

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine whether intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) could detect parotid gland abnormalities in Sjögren's syndrome (SS) patients who were not identified by conventional MRI.

MATERIALS AND

METHODS

Ten consecutive patients with clinically proven SS who were not identified by conventional MRI were assessed by IVIM MRI with a 3.0T MRI scanner. Quantitative parameters (tissue diffusivity, D; pseudodiffusion coefficient, D*; perfusion fraction, f) derived from IVIM MRI were compared between the SS group and healthy control group (n = 15). A receiver operating characteristic (ROC) curve was used to evaluate the diagnostic value of each significant parameter.

RESULTS

Excellent inter- and intrareader agreements were obtained during the measurement of D, f, and D* values (interreader, 0.980, 0.942, and 0.883; intrareader, 0.991, 0.952, and 0.896, respectively). All three parameters of the SS group were significantly higher than those of the healthy group (D, 1.049 ± 0.056 × 10(-3) mm(2) /s vs. 0.976 ± 0.116 × 10(-3) mm(2) /s, P = 0.012; D*, 20.410 ± 1.786 × 10(-3) mm(2) /s vs. 18.764 ± 2.433 × 10(-3) mm(2) /s, P = 0.013; f, 0.207 ± 0.003 vs. 0.182 ± 0.002, P = 0.004). ROC analysis showed that the f value had the best diagnostic performance (AUC, 0.712; Sensitivity, 0.80; Specificity, 0.57; Cutoff value, 0.185) in detecting the parotid gland abnormalities in early SS patients.

CONCLUSION

IVIM MRI detected parotid gland abnormalities in early-stage SS patients. J. Magn. Reson. Imaging 2016;43:1455-1461.

Для цитирования: Su Guo-Yi, Xu Xiao-Quan, Wang Yan-Yan, Hu Hao, Shen Jie, Hong Xun-Ning, Shi Hai-Bin, Wu Fei-Yun. Feasibility study of using intravoxel incoherent motion mri to detect parotid gland abnormalities in early-stage Sjögren syndrome patients.. Journal of magnetic resonance imaging : JMRI. 2015. DOI: 10.1002/jmri.25096.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.