Distinguishing early-stage nasopharyngeal carcinoma from benign hyperplasia using intravoxel incoherent motion diffusion-weighted MRI.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ai Qi-Yong, King Ann D, Chan Janet S M, Chen Weitian, Chan K C Allen, Woo John K S, Zee Benny C Y, Chan Anthony T C, Poon Darren M C, Ma Brigette B Y, Hui Edwin P, Ahuja Anil T, Vlantis Alexander C, Yuan Jing

Аннотация

OBJECTIVES: MRI can detect early-stage nasopharyngeal carcinoma (NPC), but the detection is more challenging in early-stage NPCs because they must be distinguished from benign hyperplasia in the nasopharynx. This study aimed to determine whether intravoxel incoherent motion diffusion-weighted imaging (IVIM DWI) MRI could distinguish between these two entities.

METHODS: Thirty-four subjects with early-stage NPC and 30 subjects with benign hyperplasia prospectively underwent IVIM DWI. The mean pure diffusion coefficient (D), pseudo-diffusion coefficient (D*), perfusion fraction (f) and apparent diffusion coefficient (ADC) values were calculated for all subjects and compared between the 2 groups using Student's t test. Receiver operating characteristics with the area under the curve (AUC) was used to identify the optimal threshold for all significant parameters, and the corresponding diagnostic performance was calculated. A p value of < 0.05 was considered statistically significant.

RESULTS: Compared with benign hyperplasia, early-stage NPC exhibited a significantly lower D mean (0.64 ± 0.06 vs 0.87 ± 0.11 × 10-3 mm2/s), ADC0-1000 mean (0.77 ± 0.08 vs 1.00 ± 0.13 × 10-3 mm2/s), ADC300-1000 (0.63 ± 0.05 vs 0.86 ± 0.10 × 10-3 mm2/s) and a higher D* mean (32.66 ± 4.79 vs 21.96 ± 5.21 × 10-3 mm2/s) (all p < 0.001). No significant difference in the f mean was observed between the two groups (p = 0.216). The D and ADC300-1000 mean had the highest AUC of 0.985 and 0.988, respectively, and the D mean of < 0.75 × 10-3 mm2/s yielded the highest sensitivity, specificity and accuracy (100%, 93.3% and 96.9%, respectively) in distinguishing early-stage NPC from benign hyperplasia.

CONCLUSION: DWI has potential to distinguish early-stage NPC from benign hyperplasia and D and ADC300-1000 mean were the most promising parameters.

KEY POINTS: • Diffusion-weighted imaging has potential to distinguish early-stage nasopharyngeal carcinoma from benign hyperplasia in the nasopharynx. • The pure diffusion coefficient, pseudo-diffusion coefficient from intravoxel incoherent motion model and apparent diffusion coefficient from conventional diffusion-weighted imaging were significant parameters for distinguishing these two entities in the nasopharynx. • The pure diffusion coefficient, followed by apparent diffusion coefficient, may be the most promising parameters to be used in screening studies to help detect early-stage nasopharyngeal carcinoma.