MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13014-015-0371-2

Медицинская библиотека · Radiation oncology (London, England) · 2015

Prospective longitudinal assessment of parotid gland function using dynamic quantitative pertechnate scintigraphy and estimation of dose-response relationship of parotid-sparing radiotherapy in head-neck cancers.

Gupta Tejpal, Hotwani Chandni, Kannan Sadhana, Master Zubin, Rangarajan Venkatesh, Murthy Vedang, Budrukkar Ashwini, Ghosh-Laskar Sarbani, Agarwal Jai Prakash

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To estimate dose-response relationship using dynamic quantitative (99m)Tc-pertechnate scintigraphy in head-neck cancer patients treated with parotid-sparing conformal radiotherapy.

METHODS

Dynamic quantitative pertechnate salivary scintigraphy was performed pre-treatment and subsequently periodically after definitive radiotherapy. Reduction in salivary function following radiotherapy was quantified by salivary excretion fraction (SEF) ratios. Dose-response curves were modeled using standardized methodology to calculate tolerance dose 50 (TD50) for parotid glands.

RESULTS

Salivary gland function was significantly affected by radiotherapy with maximal decrease in SEF ratios at 3-months, with moderate functional recovery over time. There was significant inverse correlation between SEF ratios and mean parotid doses at 3-months (r = -0.589, p<0.001); 12-months (r = -0.554, p<0.001); 24-months (r = -0.371, p = 0.002); and 36-months (r=-0.350, p=0.005) respectively. Using a post-treatment SEF ratio <45% as the scintigraphic criteria to define severe salivary toxicity, the estimated TD50 value with its 95% confidence interval (95% CI) for the parotid gland was 35.1Gy (23.6-42.6Gy), 41.3Gy (34.6-48.8Gy), 55.9Gy (47.4-70.0Gy) and 64.3Gy (55.8-70.0Gy) at 3, 12, 24, and 36-months respectively.

CONCLUSIONS

There is consistent decline in parotid function even after conformal radiotherapy with moderate recovery over time. Dynamic quantitative pertechnate scintigraphy is a simple, reproducible, and minimally invasive test of major salivary gland function.

Для цитирования: Gupta Tejpal, Hotwani Chandni, Kannan Sadhana, Master Zubin, Rangarajan Venkatesh, Murthy Vedang, Budrukkar Ashwini, Ghosh-Laskar Sarbani, Agarwal Jai Prakash. Prospective longitudinal assessment of parotid gland function using dynamic quantitative pertechnate scintigraphy and estimation of dose-response relationship of parotid-sparing radiotherapy in head-neck cancers.. Radiation oncology (London, England). 2015. DOI: 10.1186/s13014-015-0371-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.