Diagnostic Accuracy of Different Criteria of Pharmaco-penile Duplex Sonography for Venous Erectile Dysfunction.
Аннотация
OBJECTIVES
The aim of this study was to analyze the diagnostic accuracy of different criteria of pharmaco-penile duplex sonography in venous erectile dysfunction (ED).
METHODS
The following parameters were measured after an intracavernous injection test in patients with ED from May 2016 to February 2017 at our hospital: diameter, peak systolic velocity, end-diastolic velocity, and resistance index of the cavernous artery; diameter and peak velocity (if leak occurred) of the deep dorsal vein. Three ultrasonographic diagnostic criteria of venous ED were applied. Criterion A: continuous blood flow signals in the deep dorsal vein, peak velocity greater than 3 cm/s, peak systolic velocity greater than 30 cm/s, end-diastolic velocity greater than 5 cm/s; Criterion B: resistance index less than 0.89 and other parameters corresponding with Criterion A; Criterion C: resistance index less than 0.80 and other parameters corresponding with Criterion A. The diagnostic results of each criterion were compared with the cavernosographic results.
RESULTS
Thirty-six patients were diagnosed as venous ED by cavernosography in 54 ED cases. The diagnostic specificity, sensitivity, and accuracy of Criterion A were 70.6%, 91.7%, and 84.9%, respectively. Those of Criterion B were 82.4%, 69.4%, and 73.6%, while the results for Criterion C were 94.1%, 33.3%, and 52.8%, respectively. Criterion A had the highest diagnostic accuracy, the largest area under the receiver operating characteristic curve (area = 0.811), and the highest consistency (kappa = 0.642) with the cavernosographic results in the 3 criteria. The difference was statistically significant (P < .05).
CONCLUSIONS
Among the 3 commonly used ultrasonographic criteria, Criterion A is most appropriate in the diagnosis of venous ED.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.