MedElevator Войти в исследования
← Поиск публикаций

DOI 10.12998/wjcc.v14.i1.112880

Медицинская библиотека · World journal of clinical cases · 2026

Key role of Levitt's carbon monoxide breath test in revealing coexistent Gilbert syndrome and erythropoietic protoporphyria: A case report.

Kang Ling-Ling, Zhang Hou-De

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

It is challenging to diagnose isolated hyperbilirubinemia with rare and complex etiologies under the constraints of traditional testing conditions. Herein, we present a rare case of coexisting Gilbert syndrome (GS) and erythropoietic protoporphyria (EPP), which has not been previously documented.

CASE SUMMARY: We present a rare case of coexisting GS and EPP in a 23-year-old Chinese male with a long history of jaundice and recently found splenomegaly. Serial non-specific hemolysis screening tests yielded inconsistent results, and investigations for common hemolytic etiologies were negative. However, Levitt's carbon monoxide breath test, which measures erythrocyte lifespan (the gold-standard marker of hemolysis), demonstrated significant hemolysis, revealing a markedly shortened erythrocyte lifespan of 11 days (normal average 120 days). Genetic testing subsequently confirmed EPP with a homozygous ferrochelatase gene mutation and GS with a heterozygous uridine diphosphate glucuronosyl transferase 1A1 gene mutation.

CONCLUSION

The rapid, non-invasive Levitt's carbon monoxide breath test resolved the diagnostic challenge posed by a rare and complex cause of hyperbilirubinemia.

Для цитирования: Kang Ling-Ling, Zhang Hou-De. Key role of Levitt's carbon monoxide breath test in revealing coexistent Gilbert syndrome and erythropoietic protoporphyria: A case report.. World journal of clinical cases. 2026. DOI: 10.12998/wjcc.v14.i1.112880.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.