MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1117/1.jbo.22.5.055006

Медицинская библиотека · Journal of biomedical optics · 2017

Development and validation of a noncontact spectroscopic device for hemoglobin estimation at point-of-care.

Sarkar Probir Kumar, Pal Sanchari, Polley Nabarun, Aich Rajarshi, Adhikari Aniruddha, Halder Animesh, Chakrabarti Subhananda, Chakrabarti Prantar, Pal Samir Kumar

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

Anemia severely and adversely affects human health and socioeconomic development. Measuring hemoglobin with the minimal involvement of human and financial resources has always been challenging. We describe a translational spectroscopic technique for noncontact hemoglobin measurement at low-resource point-of-care settings in human subjects, independent of their skin color, age, and sex, by measuring the optical spectrum of the blood flowing in the vascular bed of the bulbar conjunctiva. We developed software on the LabVIEW platform for automatic data acquisition and interpretation by nonexperts. The device is calibrated by comparing the differential absorbance of light of wavelength 576 and 600 nm with the clinical hemoglobin level of the subject. Our proposed method is consistent with the results obtained using the current gold standard, the automated hematology analyzer. The proposed noncontact optical device for hemoglobin estimation is highly efficient, inexpensive, feasible, and extremely useful in low-resource point-of-care settings. The device output correlates with the different degrees of anemia with absolute and trending accuracy similar to those of widely used invasive methods. Moreover, the device can instantaneously transmit the generated report to a medical expert through e-mail, text messaging, or mobile apps.

Для цитирования: Sarkar Probir Kumar, Pal Sanchari, Polley Nabarun, Aich Rajarshi, Adhikari Aniruddha, Halder Animesh, Chakrabarti Subhananda, Chakrabarti Prantar, Pal Samir Kumar. Development and validation of a noncontact spectroscopic device for hemoglobin estimation at point-of-care.. Journal of biomedical optics. 2017. DOI: 10.1117/1.jbo.22.5.055006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.