MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.heliyon.2024.e30871

Медицинская библиотека · Heliyon · 2024

Investigation of mechanical strength and structure of corneal graft-host junction.

Chittajallu Sai Naga Sri Harsha, Gururani Himanshu, Jakati Saumya, Basu Sayan, Vaddavalli Pravin Krishna, Tse Kwong Ming, Chinthapenta Viswanath

СтатьяПеревод пока не подготовлен

Аннотация

Dehiscence is a common complication of corneal transplant surgery involving separating the graft from the host eye. The present article aims to investigate fundamental insights into the mechanical and structural aspects of the graft-host junction (GHJ) of a graft that survived in a patient for 13 years after penetrating keratoplasty (PK). Additionally, it adopts the sutur retention strength (SRS) test procedure defined in ISO:7198-2016 and aims to provide a comprehensive test protocol to study the biomechanics of the GHJ in extracted PK buttons. A 9 mm corneal button with GHJ was extracted from a 46-year-old patient who underwent PK 13 years back. The strength of the GHJ was quantified using the SRS test. Corresponding control results were obtained from the SRS tests of a corneoscleral button with no history of any refractive procedure. Birefringence, histological, and scanning electron microscopy (SEM) imaging were used to visualize the microstructural details of the GHJ. The strength of the GHJ was observed to be ten times lower than the native cornea. Histopathological features, such as fragmented Bowman's layer, and fibrosis with a clear demarcation line between host and graft tissue, were observed at the GHJ, suggesting a weak bond across the GHJ. The low strength of the GHJ in PK indicates the high susceptibility of the GHJ towards wound dehiscence.

Для цитирования: Chittajallu Sai Naga Sri Harsha, Gururani Himanshu, Jakati Saumya, Basu Sayan, Vaddavalli Pravin Krishna, Tse Kwong Ming, Chinthapenta Viswanath. Investigation of mechanical strength and structure of corneal graft-host junction.. Heliyon. 2024. DOI: 10.1016/j.heliyon.2024.e30871.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.