PURPOSE: To evaluate the use of a deep learning noise reduction model on swept source optical coherence tomography volumetric scans.

METHODS

Three groups of images including single-line highly averaged foveal scans (averaged images), foveal B-scans from volumetric scans using no averaging (unaveraged images), and deep learning denoised versions of the latter (denoised images) were obtained. We evaluated the potential increase in the signal-to-noise ratio by evaluating the contrast-to-noise ratio of the resultant images and measured the multiscale structural similarity index to determine whether the unaveraged and denoised images held true in structure to the averaged images. We evaluated the practical effects of denoising on a popular metric of choroidal vascularity known as the choroidal vascularity index.

RESULTS

Ten eyes of 10 subjects with a mean age of 31 years (range 24-64 years) were evaluated. The deep choroidal contrast-to-noise ratio mean values of the averaged and denoised image groups were similar (7.06 vs. 6.81, P = 0.75), and both groups had better maximum contrast-to-noise ratio mean values (27.65 and 46.34) than the unaveraged group (14.75; P = 0.001 and P < 0.001, respectively). The mean multiscale structural similarity index of the average-denoised images was significantly higher than the one from the averaged--unaveraged images (0.85 vs. 0.61, P < 0.001). Choroidal vascularity index values from averaged and denoised images were similar (71.81 vs. 71.16, P = 0.554).

CONCLUSION

Using three different metrics, we demonstrated that the deep learning denoising model can produce high-quality images that emulate, and may exceed, the quality of highly averaged scans.

Для цитирования: Ledesma-Gil Gerardo, Mao Zaixing, Liu Jonathan, Spaide Richard F. DENOISING SWEPT SOURCE OPTICAL COHERENCE TOMOGRAPHY VOLUMETRIC SCANS USING A DEEP LEARNING MODEL.. Retina (Philadelphia, Pa.). 2022. DOI: 10.1097/iae.0000000000003348.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.