Journal of medical radiation sciences · 2023
Impact of bowel space contouring variability on radiation dose and volume assessments in treatment planning for gynaecologic cancers.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kraja Fatjona, Kauweloa Kevin, Ganju Rohit G, Hoover Andrew C
Аннотация
INTRODUCTION: Correlations between radiation dose/volume measures and small bowel (SB) toxicity are inconsistent in the medical literature. We assessed the impact of inter-provider variation in bowel bag contouring technique on estimates of radiation dose received by the SB during pelvic radiotherapy.
METHODS: Ten radiation oncologists contoured rectum, bladder and bowel bags on treatment planning computed tomography (CT) scans of two patients receiving adjuvant radiation for endometrial cancer. A radiation plan was generated for each patient and used to determine the radiation dose/volume for each organ. Kappa statistics were applied to assess the inter-provider contouring agreement, and Levene test evaluated the homogeneity of variance for radiation dose/volume metrics, including the V45Gy (cm3 ).
RESULTS: The bowel bag showed greater variation in radiation dose/volume estimates compared to the bladder and rectum. The V45Gy ranged from 163 to 384 cm3 for data set A and 109 to 409 cm3 for dataset B. Kappa values were 0.82/0.83, 0.92/0.92 and 0.94/0.86 for the bowel bag, rectum, and bladder on data sets A/B, demonstrating lower inter-provider agreement for bowel bag compared with bladder and rectum.
CONCLUSION: Inter-provider contouring variability is more significant for the bowel bag than the rectum and bladder, with an associated greater variability in dose and volume estimates during radiation planning.
METHODS: Ten radiation oncologists contoured rectum, bladder and bowel bags on treatment planning computed tomography (CT) scans of two patients receiving adjuvant radiation for endometrial cancer. A radiation plan was generated for each patient and used to determine the radiation dose/volume for each organ. Kappa statistics were applied to assess the inter-provider contouring agreement, and Levene test evaluated the homogeneity of variance for radiation dose/volume metrics, including the V45Gy (cm3 ).
RESULTS: The bowel bag showed greater variation in radiation dose/volume estimates compared to the bladder and rectum. The V45Gy ranged from 163 to 384 cm3 for data set A and 109 to 409 cm3 for dataset B. Kappa values were 0.82/0.83, 0.92/0.92 and 0.94/0.86 for the bowel bag, rectum, and bladder on data sets A/B, demonstrating lower inter-provider agreement for bowel bag compared with bladder and rectum.
CONCLUSION: Inter-provider contouring variability is more significant for the bowel bag than the rectum and bladder, with an associated greater variability in dose and volume estimates during radiation planning.