m+Medelevator.RU
← Поиск публикаций
Nanoscale advances · 2026

Deep-hole array structure for highly sensitive fluorescence imaging of cells via inverted microscopy.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Nawa Yasunori, Shimizu Atsushi, Shigeto Hajime, Yamamura Shohei, Tawa Keiko

Аннотация

In this study, a plasmonic chip with a deep-hole array (DHA) structure enhanced fluorescence, enabling highly sensitive detection of targets via inverted fluorescence microscopy. Inverted microscopes are particularly suitable for detecting membrane proteins at the cell-substrate interface, where the cell membrane spreads in a single plane. Fluorescence enhancement should be homogeneous for high-sensitivity imaging across a wide field of view. However, in surface-plasmon-mediated enhancement, a periodic nanostructure covered with a thin metal film typically reduces the transmitted light and hinders observation via inverted microscopy. Therefore, we used a periodic DHA with a depth of 422 nm. The deep-hole structure enlarges the holes' inner areas, including the sidewalls, thus effectively reducing the metal thickness within the holes. The resulting increase in optical transmittance improved the fluorescence intensity detected by an inverted microscope. Although the transmittance of the DHA structure remained below 10% compared with that of a cover slip, it was more than 50-fold higher than that of the conventional hole-array structure (30 nm depth), resulting in an approximately 70-fold higher fluorescence intensity in observations of fluorescent particles with 0.2 µm diameters. The fluorescence enhancement achieved by the DHA plasmonic chip was further confirmed using biological samples. The imaging of breast cancer cells labeled with APC-EpCAM antibodies demonstrated that EpCAMs distributed on the cell membrane at the substrate interface, which were not discernible on a cover slip, were clearly detectable with high sensitivity. These findings establish the proposed DHA plasmonic chip as a powerful platform for highly sensitive fluorescence detection with potential applications in single-nanoparticle analysis and cellular bioimaging.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты