MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mcg.0000000000001982

Медицинская библиотека · Journal of clinical gastroenterology · 2025

Comparation of 5 ml and 10 ml Negative Pressures with Wet-suction Techniques for EUS-FNA of Solid Lesions: A Single-center Randomized Controlled Trial.

Zhu Yuchun, Su Yang, Yang Peng, Li Jiaojun, Yu Tai, Wang Yi, Zhou Xi, Zhao Ming, Sun Xiaobin, Shan Jing

СтатьяРандомизированное исследованиеСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVES

The negative pressure selectable for the wet-suction technique remains uncertain. The aim was to investigate the quality of sampling and diagnostic accuracy with solid lesions by 5 mL and 10 mL negative pressure with wet-suction techniques.

METHODS

This is a single-center, crossover, randomized controlled trial conducted with a random sampling technique. In all, 160 patients consecutively undergoing EUS-FNA for solid lesions were randomized in a ratio of 1:1 into 2 groups, the 5 mL and 10 mL negative pressure wet-suction group. The main outcome was to compare the sample quality between the 2 groups. The secondary outcome was to compare the histologic and cytologic diagnostic accuracy of solid lesions.

RESULTS

Pancreatic (n=129) and nonpancreatic (n=27) lesions from 156 lesions were examined. The sample quality concluding cellularity, adequacy, integrity, and blood contamination were comparable between the 2 groups. However, in subgroup analysis, we found 19G FNA provided more integrity of specimen in 5 mL than in 10 mL group (100% vs. 82.9%, P =0.025). In contrast, this benefit was not noteworthy in the 22G FNA subgroup. And there was no statistically significant in histologic (87.82% vs. 87.18%, P =1.000) and cytologic (78.85% vs. 80.77%, P =0.778) accuracy between 5 mL and 10 mL groups.

CONCLUSION

When using the wet-suction technique, 5 mL and 10 mL negative pressure offer equivalent sample quality and diagnostic accuracy. However, the 19G FNA can obtain better sample quality with 5 mL negative pressure than 10 mL negative pressure.

Для цитирования: Zhu Yuchun, Su Yang, Yang Peng, Li Jiaojun, Yu Tai, Wang Yi, Zhou Xi, Zhao Ming, Sun Xiaobin, Shan Jing. Comparation of 5 ml and 10 ml Negative Pressures with Wet-suction Techniques for EUS-FNA of Solid Lesions: A Single-center Randomized Controlled Trial.. Journal of clinical gastroenterology. 2025. DOI: 10.1097/mcg.0000000000001982.