MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.acra.2026.06.063

Медицинская библиотека · Academic radiology · 2026

Habitat-Based Radiomic Quantification of Intratumoral Heterogeneity on Digital Breast Tomosynthesis for Predicting HER2 Status in Invasive Breast Cancer.

Miao Yifan, Liu Jie, Gao Yiping, Chen Shuangqing

СтатьяПеревод пока не подготовлен

Аннотация

UNLABELLED: RATIONALE AND

OBJECTIVE

This exploratory study aims to develop and validate a model on Digital Breast Tomosynthesis (DBT), using habitat‑based radiomics to quantify Intratumoral Heterogeneity (ITH) for non-invasive pre-operative prediction of HER2 status in invasive breast cancer.

MATERIALS AND

METHODS

444 people with invasive breast cancer were studied (2018.1-2025.6). They were classified as HER2-positive, HER2-low, or HER2-zero. After radiomics feature extraction and dimensionality reduction, we developed Intra, ITH, and combined models using multilayer perceptron (MLP) and logistic regression (LR) classifiers. Two classification tasks were performed: Task 1 is to differentiate HER2-positive versus HER2-negative individuals. Task 2, which is to differentiate individuals with HER2-low versus HER2-zero status.

RESULTS

The ITH model achieved good performance on the test set in Task 1(AUC, 0.934; 95% CI: 0.881, 0.988), while the combined model achieved a numerically higher AUC of 0.940 (95% CI: 0.894, 0.986). In Task 2, the ITH model performed comparably to the conventional Intra model, whereas the combined model produced the most favorable results on the test set (AUC, 0.849; 95% CI: 0.740, 0.958).

CONCLUSIONS

The combined model performed best at discriminating HER2-positive, HER2-low, and HER2-zero cases. Habitat-based radiomics quantifying ITH, thereby facilitating the prediction of HER2 status.

Для цитирования: Miao Yifan, Liu Jie, Gao Yiping, Chen Shuangqing. Habitat-Based Radiomic Quantification of Intratumoral Heterogeneity on Digital Breast Tomosynthesis for Predicting HER2 Status in Invasive Breast Cancer.. Academic radiology. 2026. DOI: 10.1016/j.acra.2026.06.063.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.