DOI 10.1016/j.mri.2010.06.009

Медицинская библиотека · Magnetic resonance imaging · 2010

MR Imaging of total hip arthroplasty: comparison among sequences to study the sciatic nerve at 1.5 T.

Tagliafico Alberto, Podestà Andrea, Assini Andrea, Boccacini Leonardo, Serafini Giovanni, Calabrese Massimo, Martinoli Carlo

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: This study was done to test a series of MR sequences for evaluating the sciatic nerve after total hip arthroplasty (THA).

MATERIAL AND

METHODS

The study protocol was approved by the institutional review board. Informed consent was obtained from all patients. Twenty-five patients (11 men and 14 women mean age: 62.3±5.7 years) with THA were included in this prospective study. MRI protocol included sequences that were preliminarily tailored for nerve imaging in patients with THA: proton density (PD)-weighted turbo SE, T1-weighted turbo SE (TSE) 3 mm thickness, T1-weighted turbo SE (TSE) 6 mm thickness, T1-weighted turbo SE with high bandwidth (TSE hBW), T2- weighted TSE, T2-weighted with fat saturation and short-tau inversion recovery (STIR). For each sequence, we evaluated the visibility of the sciatic nerve using a semiquantitative score (0=total masking; 1=insufficient visibility; 2=sufficient visibility; 3=optimal visibility). The sum of the scores given to each sequence was divided by the maximal sum, obtaining a percentage visibility index. Friedman and sign tests were used for statistical analysis.

RESULTS

MR examination time was approximately 40 min. No patients reported pain, heat or symptoms related to nerve stimulation. The visibility index ranged between 88% and 70% for the first four sequences. The T1-weighted TSE hBW sequence had the best visibility index (P<.05). The visibility indexes of the first four sequences were significantly higher (P<.004, sign test) than those of the remaining three sequences.

CONCLUSION

The sciatic nerve could be studied at 1.5 T in patients following THA. The nerve is better visualized with T1-weighted TSE hBW sequences. On T2-weighted sequences and STIR, the visibility of the nerve is low.

Для цитирования: Tagliafico Alberto, Podestà Andrea, Assini Andrea, Boccacini Leonardo, Serafini Giovanni, Calabrese Massimo, Martinoli Carlo. MR Imaging of total hip arthroplasty: comparison among sequences to study the sciatic nerve at 1.5 T.. Magnetic resonance imaging. 2010. DOI: 10.1016/j.mri.2010.06.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.