MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13244-023-01397-7

Медицинская библиотека · Insights into imaging · 2023

Mucosal healing assessment in Crohn's disease with normalized iodine concentration from dual-energy CT enterography: comparison with endoscopy.

Zhu Chao, Hu Jing, Rong Chang, Zhou Jianhua, Zhang Bo, Gao Yankun, Li Cuiping, Li Jianying, Wu Xingwang

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Mucosal healing (MH) is an important goal in the treatment of patients with Crohn's disease (CD). Noninvasive assessment of MH with normalized iodine concentration (NIC) is unknown.

METHODS

In this retrospective study, 94 patients with diagnosed CD underwent endoscopy and dual-energy CT enterography (DECTE) at the post-infliximab treatment review. Two radiologists reviewed DECTE images by consensus for assessing diseased bowel segments of the colon or terminal ileum, and the NIC was measured. Patients were divided into transmural healing (TH), MH and non-MH groups. The diagnostic performance of the MH and non-MH groups with clinical factors and NIC was assessed utilizing receiver operating characteristic (ROC) curve analysis.

RESULTS

Of the 94 patients included in our study, 8 patients achieved TH, 34 patients achieved MH, and 52 patients did not achieve MH at the post-IFX treatment review. The area under the ROC curve (AUC), sensitivity, specificity, and accuracy values were 0.929 (95% confidence interval [CI] 0.883-0.967), 0.853, 0.827, and 0.837, respectively, for differentiating MHs from non-MHs, and the optimal NIC threshold was 0.448. The AUC of the combined model for distinguishing MHs from non-MHs in CD patients, which was based on the NIC and calprotectin, was 0.964 (95% CI 0.935-0.987).

CONCLUSIONS

The normalized iodine concentration measurement in DECTE has good performance in assessment MH in patients with CD. Iodine concentration from DECTE can be used as a radiologic marker for MH.

Для цитирования: Zhu Chao, Hu Jing, Rong Chang, Zhou Jianhua, Zhang Bo, Gao Yankun, Li Cuiping, Li Jianying, Wu Xingwang. Mucosal healing assessment in Crohn's disease with normalized iodine concentration from dual-energy CT enterography: comparison with endoscopy.. Insights into imaging. 2023. DOI: 10.1186/s13244-023-01397-7.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.