DOI 10.3390/biomedicines11020645
First Live-Experience Session with PET/CT Specimen Imager: A Pilot Analysis in Prostate Cancer and Neuroendocrine Tumor.
Аннотация
OBJECTIVE
to evaluate the feasibility of the intra-operative application of a specimen PET/CT imager in a clinical setting.
MATERIALS AND
METHODS
this is a pilot analysis performed in three patients who received an intra-operative administration of 68Ga-PSMA-11 (n = 2) and 68Ga-DOTA-TOC (n = 1), respectively. Patients were administrated with PET radiopharmaceuticals to perform radio-guided surgery with a beta-probe detector during radical prostatectomy for prostate cancer (PCa) and salvage lymphadenectomy for recurrent neuroendocrine tumor (NET) of the ileum, respectively. All procedures have been performed within two ongoing clinical trials in our Institute (NCT05596851 and NCT05448157). Pathologic assessment with immunohistochemistry (PSMA-staining and SSA immunoreactivity) was considered as standard of truth. Specimen images were compared with baseline PET/CT images and histopathological analysis.
RESULTS
Patients received 1 MBq/Kg of 68Ga-PSMA-11 (PCa) or 1.2 MBq/Kg of 68Ga-DOTA-TOC (NET) prior to surgery. Specimens were collected, positioned in the dedicated specimen container, and scanned to obtain high-resolution PET/CT images. In all cases, a perfect match was observed between the findings detected by the specimen imager and histopathology. Overall, the PET spatial resolution was sensibly higher for the specimen images compared to the baseline whole-body PET/CT images. Furthermore, the use of the PET/CT specimen imager did not significantly interfere with any procedures, and the overall length of the surgery was not affected using the PET/CT specimen imager. Finally, the radiation exposure of the operating theater staff was lower than 40 µSv per procedure (range 26-40 μSv).
CONCLUSIONS
the image acquisition of specimens obtained by patients who received intra-surgery injections of 68Ga-PSMA-11 and 68Ga-DOTA-TOC was feasible and reliable also in a live-experience session and has been easily adapted to surgery daily practice. The high sensitivity, together with the evaluation of intra-lesion tumor heterogeneity, were the most relevant results since the data derived from specimen PET/CT imaging matched perfectly with the histopathological analysis.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.