MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12630-021-01938-y

Медицинская библиотека · Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2021

Double-lumen endotracheal tubes and bronchial blockers exhibit similar lung collapse physiology during lung isolation.

Moreault Olivier, Couture Etienne J, Provencher Steeve, Somma Jacques, Lohser Jens, Ugalde Paula A, Lemieux Jérôme, Lellouche François, Bussières Jean S

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: Double-lumen endotracheal tubes (DL-ETT) and bronchial blockers (BB) are frequently used to allow one-lung ventilation (OLV) during video-assisted thoracic surgery (VATS). Recently, faster lung collapse has been documented with a BB than with a DL-ETT. The physiologic mechanisms behind this faster collapse remained unknown. We aimed to measure ambient air absorption (Vresorb) and intra-bronchial pressure (Pairway) into the non-ventilated lung during OLV using DL-ETT and BB.

METHODS

Patients undergoing VATS and OLV for lung resection were randomly assigned to have measurements made of Vresorb or Pairway within the non-ventilated lung using either a DL-ETT or BB.

RESULTS

Thirty-nine patients were included in the analyses. The mean (standard error of the mean [SEM]) Vresorb was similar in the DL-ETT and BB groups [504 (85) vs 630 (86) mL, respectively; mean difference, 126; 95% confidence interval [CI], -128 to 380; P = 0.31]. The mean (SEM) Pairway became progressively negative in the non-ventilated lung in both the DL-ETT and the BB groups reaching [-20 (5) and -31 (10) cmH2O, respectively; mean difference, -11; 95% CI, -34 to 12; P = 0.44] at the time of the pleural opening.

CONCLUSIONS

During OLV before pleural opening, entrainment of ambient air into the non-ventilated lung occurs when the lumen of the lung isolation device is kept open. This phenomenon is prevented by occluding the lumen of the isolation device before pleural opening, resulting in a progressive build-up of negative pressure in the non-ventilated lung. Future clinical studies are needed to confirm these physiologic results and their impact on lung collapse and operative outcomes.

TRIAL REGISTRATION: www.clinicaltrials.gov (NCT02919267); registered 28 September 2016.

Для цитирования: Moreault Olivier, Couture Etienne J, Provencher Steeve, Somma Jacques, Lohser Jens, Ugalde Paula A, Lemieux Jérôme, Lellouche François, Bussières Jean S. Double-lumen endotracheal tubes and bronchial blockers exhibit similar lung collapse physiology during lung isolation.. Canadian journal of anaesthesia = Journal canadien d'anesthesie. 2021. DOI: 10.1007/s12630-021-01938-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.