Journal of endodontics · 2024
Morphology of the Physiological Foramen: II. Maxillary and Mandibular Premolars.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Wolf Thomas Gerhard, Waber Andrea Lisa, Briseño Marroquín Benjamín
Аннотация
INTRODUCTION: Information concerning the anatomy of the physiological foramen is still limited. The aim of this study was to investigate the distance between the physiological and anatomic apex, the shape and diameter of the physiological foramen in maxillary (Mx) and mandibular premolars (Mn).
METHODS: The anatomy of the apex of 229 maxillary (first: MxP1; second: MxP2) and 221 mandibular premolars (first: MnP1; second: MnP2) from a mixed Swiss-German population was investigated by means of microcomputed tomography and 3-dimensional software imaging.
RESULTS: The following results were obtained in the presence of a main physiological foramen. 1. The distance between the physiological and anatomic foramen was 0.29-0.99 mm (MxP1), 0.21-1.03 mm (MxP2), 0.13-0.8 (MnP1), and 0.15-1.41 (MnP2). 2. The mean narrow and wide diameters of the physiological foramen were 0.19-0.33 mm (MxP1), 0.25-0.42 mm (MxP2), 0.28-0.37 (MnP1), and 0.28-0.40 (MnP2). 3. The most common physiological foramen shape was oval (66.7% MxP1, 89.7% MxP2, 91.8% MnP1, 64.4% MnP2).
CONCLUSION: Considering the recommended preparation sizes based on a size corresponding to the friction, that is at the narrowest point in the area of the apical constriction (physiological foramen), and within the limitations of this ex vivo microcomputed tomography study, a final preparation size could be chosen when considering the pertaining morphologic considerations; yet, to a minimum ISO 30 size.
METHODS: The anatomy of the apex of 229 maxillary (first: MxP1; second: MxP2) and 221 mandibular premolars (first: MnP1; second: MnP2) from a mixed Swiss-German population was investigated by means of microcomputed tomography and 3-dimensional software imaging.
RESULTS: The following results were obtained in the presence of a main physiological foramen. 1. The distance between the physiological and anatomic foramen was 0.29-0.99 mm (MxP1), 0.21-1.03 mm (MxP2), 0.13-0.8 (MnP1), and 0.15-1.41 (MnP2). 2. The mean narrow and wide diameters of the physiological foramen were 0.19-0.33 mm (MxP1), 0.25-0.42 mm (MxP2), 0.28-0.37 (MnP1), and 0.28-0.40 (MnP2). 3. The most common physiological foramen shape was oval (66.7% MxP1, 89.7% MxP2, 91.8% MnP1, 64.4% MnP2).
CONCLUSION: Considering the recommended preparation sizes based on a size corresponding to the friction, that is at the narrowest point in the area of the apical constriction (physiological foramen), and within the limitations of this ex vivo microcomputed tomography study, a final preparation size could be chosen when considering the pertaining morphologic considerations; yet, to a minimum ISO 30 size.