MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/dmfr/twae008

Медицинская библиотека · Dento maxillo facial radiology · 2024

Effect of metal artefact reduction level on the assessment of dental implant positioning by cone-beam computed tomography.

Capel Camila Porto, da Motta Raphael Jurca Gonçalves, Pauwels Ruben, Gaêta-Araujo Hugo, Oliveira-Santos Christiano, Tirapelli Camila

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study evaluated the effect of metal artefact reduction (MAR) level and tube current on the assessment of dental implant positioning relative to the mandibular canal (MC) through cone-beam computed tomography (CBCT).

METHODS

Titanium dental implants were placed in dried mandibles at 0.5-mm superior to the MC (group 1/n = 8) and 0.5-mm inside the MC with perforation of the cortex (group 2/n = 10). CBCT scans were obtained with different levels of MAR (off, medium, and high) and 2 tube currents (4 and 8 mA). Four examiners analysed the images and scored the contact between the implant and the MC using a 5-point scale. Sensitivity, specificity, area under receiver operating characteristic curve (ROC), and frequency of scores were calculated. Data were compared with analysis of variance 2-way and Tukey's test and scores with Chi-square test.

RESULTS

Specificity and area under ROC curve decreased significantly when MAR level was high compared with MAR-medium and MAR-off. The frequency of score 3 (inconclusive) was the highest, and scores 1 and 5 (definitely no contact and definitely contact, respectively) were the lowest with MAR-high, regardless of the tube current. When MAR was off, there were higher frequencies of scores 1 and 5.

CONCLUSIONS

The level of MAR influences the assessment of the relationship between the dental implant and the MC. MAR-high led to lower diagnostic accuracy compared with MAR-medium and off.

ADVANCES IN KNOWLEDGE: This article shows that high level of MAR can interfere in the diagnostic of dental implant positioning relative to the MC, decreasing its accuracy.

Для цитирования: Capel Camila Porto, da Motta Raphael Jurca Gonçalves, Pauwels Ruben, Gaêta-Araujo Hugo, Oliveira-Santos Christiano, Tirapelli Camila. Effect of metal artefact reduction level on the assessment of dental implant positioning by cone-beam computed tomography.. Dento maxillo facial radiology. 2024. DOI: 10.1093/dmfr/twae008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.